You must verify the HA state of the chassis, and, if necessary, update the state to match your system configuration.
- In Maintenance mode, from either controller module, display the HA state of the local controller module and chassis: ha-config show
The HA state should be the same for all components.
- Proceed based on the results of Step 1.
If the displayed system state for the chassis... | Then... |
---|
Matches your system configuration | Go to the next step. |
Does not match your system configuration | Set the HA state for the chassis: ha-config modify chassis HA-state The value for HA-state can be one of the following: - Confirm that the setting has changed: ha-config show
|
- If you have not already done so, recable the rest of your system.
- The next step depends on your system configuration.
If your system is in... | Then... |
---|
An HA pair with a second controller module | Exit Maintenance mode: halt The LOADER prompt appears. |