General problem determination procedures
Use the information in this section to resolve problems if the event log does not contain specific errors or the server is inoperative.
Power off the server.
Make sure that the server is cabled correctly.
- Remove or disconnect the following devices if applicable, one at a time, until you find the failure. Power on and configure the server each time you remove or disconnect a device.
Any external devices.
Surge-suppressor device (on the server).
Printer, mouse, and non-Lenovo devices.
Each adapter.
Hard disk drives.
Memory modules until you reach the minimal configuration for debugging that is supported for the server.
For SD650 V2/SD650-N V2, see ThinkSystem SD650 V2/SD650-N V2 User Guide.
To determine the minimal configuration for your server, seeMinimal configuration for debugging
section in User Guide of your high-density server.:SD650 V3: SD650 V3 User Guide
SD650-I V3: SD650-I V3 User Guide
SD650-N V3: SD650-N V3 User Guide
SD665 V3: SD665 V3 User Guide
SD665-N V3: SD665-N V3 User Guide
Power on the server.
If the problem is solved when you remove an adapter from the server, but the problem recurs when you install the same adapter again, suspect the adapter. If the problem recurs when you replace the adapter with a different one, try a different PCIe slot.
If the problem appears to be a networking problem and the server passes all system tests, suspect a network cabling problem that is external to the server.