S.3058004 : [S.3058004]
[S.3058004]
Severity
Error
User Response
Complete the following steps:
- Original UEFI settings are still present. If customer desires to continue using the original settings, select Save Settings.
- If User did not intentionally trigger the reboots, check logs for probable cause. For example, if there is a battery fault event, follow the steps to resolve that event.
- Undo recent system changes (settings or devices added). Verify that the system boots. Then, re-install options one at a time to locate the problem.
- Check IBM support site for an applicable service bulletin or firmware update that applies to this error. Update UEFI firmware if applicable.
- Remove and re-install CMOS battery for 30 seconds to clear CMOS contents. If it boots successfully, then restore system settings.
- (Trained Service technician only) Replace the system board.