Considerations for ISLs
You must determine how many ISLs you need for each FC switch fabric in the MetroCluster configuration. In some cases, instead of dedicating FC switches and ISLs to each individual MetroCluster configuration, you can share the same four switches.
ISL sharing considerations
Two separate four-node MetroCluster configurations
Two DR groups within one eight-node MetroCluster configuration
The number of ISLs required between the shared switches depends on the bandwidth of the platform models connected to the shared switches.
Consider the following aspects of your configuration when determining how many ISLs you need.
Non-MetroCluster devices should not be connected to any of the FC switches that provide the back-end MetroCluster connectivity.
The FC switch cabling for ISL sharing is the same as for the eight-node MetroCluster cabling.
The RCF files for ISL sharing are same as for the eight-node MetroCluster cabling.
You should verify that all hardware and software versions are supported.
The speed and number of ISLs must be sized to support the client load on both MetroCluster systems.
The back-end ISLs and the back-end components must be dedicated to the MetroCluster configuration only.
The ISL must use one of the supported speeds: 4 Gbps, 8 Gbps, 16 Gbps, or 32 Gbps.
The ISLs on one fabric should all be the same speed and length.
The ISLs on one fabric should all have the same topology. For example, they should all be direct links, or if your system uses WDM, then they should all use WDM.
Platform-specific ISL considerations
The number of recommended ISLs is platform-model specific. It assumes that each ISL has a 16-Gbps capacity, and it requires two ISLs for DM7000.
If the switch fabric is supporting eight nodes (two four-node configurations that are sharing ISLs), the recommended total number of ISLs for the fabric is the sum of that required for each four-node DR group. For example:
If DR group 1 includes four DM7000H systems, it requires two ISLs.
If DR group 2 includes four DM7000H systems, it requires two ISLs.
The total number of recommended ISLs for the switch fabric is four.