FQXSPMA0039G : DIMM [DIMMID] is disabled.
DIMM [DIMMID] is disabled.
This message is for the use case when an implementation has detected a Sensor has asserted.
Severity
Warning
Alert Category
Warning - Memory
Serviceable
No
SNMP Trap ID
43
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- Check if there is any other memory related message reported prior to this event.
- If the DIMM configuration was changed prior to this failure, verify that the DIMMs are installed in the correct population sequence.
- If there is any DIMM POST test failed, reseat the DIMM failed the POST memory test and the DIMMs on adjacent slots if populated. Boot to F1 setup and enable the DIMM. Reboot the system.
- If the DIMMs have been upgraded just prior to the issue, update UEFI to the latest version.
- If the problem persists, collect service data logs.
- Contact Lenovo Support.