Event ID | Message String | Severity |
---|---|---|
FQXPMCL0005I | Start to install OS. | Informational |
FQXPMCL0006I | Export raid config successfully. | Informational |
FQXPMCL0007I | Import raid config successfully. | Informational |
FQXPMCL0008I | Export uefi settings successfully. | Informational |
FQXPMCL0009I | Import uefi settings successfully. | Informational |
FQXPMCL0010I | Export bmc settings successfully. | Informational |
FQXPMCL0011I | Import bmc settings successfully. | Informational |
FQXPMEM0002I | LXPM firmware image found. Starting LXPM | Informational |
FQXPMEM0003I | LXPM has exited. Control returned to UEFI | Informational |
FQXPMEM0004I | Launching diagnostic program | Informational |
FQXPMEM0005I | boot diagnostic program success | Informational |
FQXPMER0002I | Clearing RAID configuration and internal storage | Informational |
FQXPMER0003I | RAID configuration cleared successfully | Informational |
FQXPMER0004I | Internal storage drives erased successfully | Informational |
FQXPMER0005I | All system logs cleared successfully | Informational |
FQXPMER0006I | UEFI factory default settings loaded successfully | Informational |
FQXPMER0007I | BMC factory default settings loaded successfully | Informational |
FQXPMNM0002I | Set BMC network parameters to new values. | Informational |
FQXPMOS0028I | [arg1] OS installed | Informational |
FQXPMSR0012I | Change disk drives' state successfully. | Informational |
FQXPMSR0022I | Create new virtual disk successfully. | Informational |
FQXPMSR0032I | Removed existing virtual disk successfully. | Informational |
FQXPMUP0101I | Start to update LXPM | Informational |
FQXPMUP0102I | Start to update window driver | Informational |
FQXPMUP0103I | Start to update linux driver | Informational |
FQXPMUP0104I | Start to update UEFI | Informational |
FQXPMUP0105I | Start to update BMC | Informational |
FQXPMUP0106I | Successfully updated the firmware | Informational |
FQXPMVD0003I | Update VPD data successfully. | Informational |
FQXPMCL0001K | Bootx64.efi is not found. Failed to Boot OS. | Warning |
FQXPMCL0002K | Failed to read Deployment Manager Signature from USB. | Warning |
FQXPMCL0003K | BMC communication failed: DRIVER Mount Failure. | Warning |
FQXPMCL0004K | BMC communication succeeded. Volume Name MISMATCHED. | Warning |
FQXPMCL0005K | Current System Boot Mode is Legacy. OS Clone only support UEFI Mode. | Warning |
FQXPMCL0006K | Failed to export raid config. | Warning |
FQXPMCL0007K | Failed to import raid config. | Warning |
FQXPMCL0008K | Failed to export uefi settings. | Warning |
FQXPMCL0009K | Failed to import uefi settings. | Warning |
FQXPMCL0010K | Failed to export bmc settings. | Warning |
FQXPMCL0011K | Failed import bmc settings. | Warning |
FQXPMNM0001G | Failed to set new BMC network parameters. | Warning |
FQXPMOS0001K | Bootx64.efi is not found. Failed to Boot OS. | Warning |
FQXPMOS0002K | Failed to read Deployment Manager Signature from USB. | Warning |
FQXPMOS0003K | Failed to copy Windows boot files to target | Warning |
FQXPMOS0004K | BMC Communication Failed: EMMC2USB Mount Failure. | Warning |
FQXPMOS0005K | BMC communication failed: DRIVER Mount Failure. | Warning |
FQXPMOS0006K | BMC communication succeeded. Volume Name MISMATCHED. | Warning |
FQXPMOS0007K | Failed to read License RTF file. | Warning |
FQXPMOS0008K | Please make sure the Ethernet cable has been plugged into your computer and your network settings are correct. | Warning |
FQXPMOS0009K | Current System Boot Mode is Legacy. LXPM OS installation only support UEFI Mode. | Warning |
FQXPMSR0001K | Found unsupported RAID adapter. | Warning |
FQXPMSR0011K | Failed to change disk drives' state. | Warning |
FQXPMSR0021L | Failed to create new virtual disk. | Warning |
FQXPMSR0031L | Failed to remove existing virtual disk | Warning |
FQXPMUP0001K | The system configuration does not meet the prerequisite | Warning |
FQXPMUP0002K | The selected packages are not compatible | Warning |
FQXPMUP0003K | Unable to obtain the minimum level of UEFI | Warning |
FQXPMUP0004K | Unable to obtain the installed version of UEFI | Warning |
FQXPMUP0005K | Unable to obtain the installed version of BMC | Warning |
FQXPMUP0006K | Unable to obtain the installed version of LXPM | Warning |
FQXPMUP0007K | Unable to obtain the installed version of linux driver | Warning |
FQXPMUP0008K | Unable to obtain the installed version of windows driver | Warning |
FQXPMVD0001H | Failed to get VPD data. | Warning |
FQXPMVD0002H | Failed to update the VPD data. | Warning |
FQXPMVD0011K | Failed to get the TPM/TPM card/TCM policy status | Warning |
FQXPMVD0012K | Failed to set the TPM/TPM card/TCM policy | Warning |
FQXPMEM0001M | Unable to locate LXPM firmware image | Error |
FQXPMEM0006M | Unable to locate diagnostic firmware image | Error |
FQXPMEM0007M | Diagnostic image cannot be launched as "Console Redirection" is enabled | Error |
FQXPMEM0008M | Diagnostic image cannot be launched as the image may be corrupt | Error |
FQXPMER0002M | Failed to clear RAID configuration | Error |
FQXPMER0003M | Failed to erase internal storage drives | Error |
FQXPMER0004M | Failed to clear system logs | Error |
FQXPMER0005M | Failed to load UEFI factory default settings | Error |
FQXPMER0006M | Failed to load XCC factory default settings | Error |
FQXPMSD0001M | HDD Test was interrupted by the host with a hardware or software reset | Error |
FQXPMSD0002M | A fatal error or unknown test error occurred while the device was executing its self-test | Error |
FQXPMSD0003M | self-test completed having a test element that failed and the test element that failed is not known. | Error |
FQXPMSD0004M | self-test completed having the electrical element of the test failed. | Error |
FQXPMSD0005M | self-test completed having the servo (and/or seek) test element of the test failed. | Error |
FQXPMSD0006M | self-test completed having the read element of the test failed. | Error |
FQXPMSD0007M | Hard Drive(s) not found | Error |
FQXPMSD0008M | UEFI is not ready for LXPM to send command to test hard drive. | Error |
FQXPMSD0009M | Device error is occurred when LXPM send command to test hard drive. | Error |
FQXPMSD0010M | uEFI is timeout while LXPM send command to test hard drive. | Error |
FQXPMSD0011M | The hard drive is not supported by uEFI while LXPM send command to test hard drive. | Error |
FQXPMUP0201M | BMC communication failed: EMMC2USB mount failure. Failed to update the firmware | Error |
FQXPMUP0202M | Transfer the update package error. Failed to update the firmware | Error |
FQXPMUP0203M | BMC communication failed: EMMC2USB unmount failure. Failed to update the firmware | Error |
FQXPMUP0204M | BMC communication failed: Execute the update cmd failure. Failed to update the firmware | Error |
FQXPMUP0205M | BMC communication failed: Get the update status failure.Failed to update the firmware | Error |
FQXPMUP0206M | The level of the update package is too old. Failed to update the firmware. | Error |
FQXPMUP0207M | The update package is invalid. Failed to update the firmware. | Error |
FQXPMUP0208M | Failed to execute reboot BMC command | Error |