跳至主要内容

FQXSPPW0123M : PSU [SensorName] input failure has transitioned to critical from a less severe state.

PSU [SensorName] input failure has transitioned to critical from a less severe state.

This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

Severity

Error

Alert Category

Critical - Power

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0522

SNMP Trap ID

4

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. For CRPS Premium:
    1. Check the LEDs on the PSU. If IN and OUT LED are not lit, check power cord and input voltage.
    2. If the problem persists, collect service data log.
    3. Contact Lenovo Support.
  2. For CRPS:
    1. Check the LED on the PSU. If one PSU LED is green and the other PSU LED is yellow, check power cord and input voltage.
    2. If the problem persists, collect service data log.
    3. Contact Lenovo Support.