Saltar al contenido principal

FQXSFMA0077N : SMBus failure encountered when accessing to the SPD of DIMM [arg1]. [arg2].

SMBus failure encountered when accessing to the SPD of DIMM [arg1]. [arg2].

Parameters

[arg1] DIMM slot silk label

[arg2] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"

Severity

Error

User Action

Complete the following steps:

  1. Power off the system and remove A/C power.
  2. Reseat the DIMM in the slot specified by the event message.
  3. Restore A/C power and power on the system.
  4. If the problem persists, collect support log and contact Lenovo Support.