Zum Hauptinhalt springen

FQXSPCA0004N : Numeric sensor [NumericSensorElementName] going low (lower non-recoverable) has asserted.

Numeric sensor [NumericSensorElementName] going low (lower non-recoverable) has asserted.

This message is for the use case when an implementation has detected a Lower Non-recoverable sensor going low has asserted.

Severity

Error

Alert Category

Critical - Fan Failure

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0484

SNMP Trap ID

11

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. Check the Chassis Management Module or XCC event log for any fan- or cooling-related issues.
  2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  3. Make sure that the room temperature is within operating specifications.
  4. Make sure that the processor 1 heat sink is securely installed.
  5. Make sure that the microprocessor 1 heat sink is installed correctly and the thermal material is correctly applied.
  6. Replace the identified Fan