FQXSPCA0004N : Numeric sensor [NumericSensorElementName] going low (lower non-recoverable) has asserted.
Numeric sensor [NumericSensorElementName] going low (lower non-recoverable) has asserted.
This message is for the use case when an implementation has detected a Lower Non-recoverable sensor going low has asserted.
Severity
Error
Alert Category
Critical - Fan Failure
Serviceable
Yes
SNMP Trap ID
11
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- Check the Chassis Management Module or XCC event log for any fan- or cooling-related issues.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.
- Make sure that the processor 1 heat sink is securely installed.
- Make sure that the microprocessor 1 heat sink is installed correctly and the thermal material is correctly applied.
- Replace the identified Fan
フィードバックを送る