Passa al contenuto principale

FQXSPCA0011N : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted.

Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted.

This message is for the use case when an implementation has detected an Upper Non-recoverable sensor going high has asserted.

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0498

SNMP Trap ID

0

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. Check the CMM and XCC event log for any fan, cooling or power related issues.
  2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are correctly installed in place.
  3. Make sure that the room temperature is in the range in the operating specifications.