Memory problems
Use this information to resolve issues related to memory.
Displayed system memory less than installed physical memory
- Make sure that:- No error LEDs are lit on the operator information panel. 
- No DIMM error LEDs are lit on the system board. 
- Memory mirrored channel does not account for the discrepancy. 
- The DIMMs are seated correctly. 
- You have installed the correct type of memory. 
- If you changed the memory, you updated the memory configuration in the Setup utility. 
- All banks of memory are enabled. The server might have automatically disabled a memory bank when it detected a problem, or a memory bank might have been manually disabled. 
- There is no memory mismatch when the server is at the minimum memory configuration. 
 
- Reseat the DIMMs, and then restart the server. 
- Run memory diagnostics. When you start a server and press F1, the Lenovo XClarity Provisioning Manager interface is displayed by default. You can perform memory diagnostics from this interface. From the Diagnostic page, click . 
- Check the POST error log: - If a DIMM was disabled by a systems-management interrupt (SMI), replace the DIMM. 
- If a DIMM was disabled by the user or by POST, reseat the DIMM; then, run the Setup utility and enable the DIMM. 
 
- Reseat the DIMM. 
- Restart the server. 
Multiple rows of DIMMs in a branch identified as failing
- Reseat the DIMMs; then, restart the server.
- Remove the lowest-numbered DIMM pair of those that are identified and replace it with an identical known good DIMM; then, restart the server. Repeat as necessary. If the failures continue after all identified DIMMs are replaced, go to step 4.
- Return the removed DIMMs, one at a time, to their original connectors, restarting the server after each DIMM, until a DIMM fails. Replace each failing DIMM with an identical known good DIMM, restarting the server after each DIMM replacement. Repeat step 3 until you have tested all removed DIMMs.
- Replace the lowest-numbered DIMM of those identified; then, restart the server. Repeat as necessary.
- Reverse the DIMMs between the channels (of the same processor), and then restart the server. If the problem is related to a DIMM, replace the failing DIMM.
- (Trained technician only) Replace the system board.