Skip to main content

Show replaceable drives

The show replaceableDrives command shows all replaceable drives in a storage array.

Supported Arrays

This command applies to an individual DE2000H, DE4000H, DE4000F, DE6000H, or DE6000F storage array.

Roles

To execute this command on an storage array, you must have the Storage Admin role.

Context

For each replaceable drive in the storage array, this command returns the following information:
  • The tray location and the slot location

  • The volume group name to which the drive belongs

  • The World Wide Name (WWN)

  • The status of the drive

Syntax

show replaceableDrives

Example output


Replaceable drive at Tray 0, Slot 3
Volume group: 2

World-wide name: 5000c50028785aff0000000000000000
Status:
Removed
Replaceable drive at Tray 0, Slot 23
Volume group: 2

World-wide name: 5000c500095d46df0000000000000000

Status: Removed
Replaceable drive at Tray 0, Slot 24

Volume group: 2
World-wide name:
5000c500287854d70000000000000000
Status: Removed