Show replaceable drives
The show replaceableDrives command shows all replaceable drives in a storage array.
Supported Arrays
This command applies to an individual DE2000H, DE4000H, DE4000F, DE6000H, or DE6000F storage array.
Roles
To execute this command on an storage array, you must have the Storage Admin role.
Context
For each replaceable drive in the storage array, this command returns the following information:
The tray location and the slot location
The volume group name to which the drive belongs
The World Wide Name (WWN)
The status of the drive
Syntax
show replaceableDrives
Example output
Replaceable drive at Tray 0, Slot 3
Volume group: 2
World-wide name: 5000c50028785aff0000000000000000
Status:
Removed
Replaceable drive at Tray 0, Slot 23
Volume group: 2
World-wide name: 5000c500095d46df0000000000000000
Status: Removed
Replaceable drive at Tray 0, Slot 24
Volume group: 2
World-wide name:
5000c500287854d70000000000000000
Status: Removed
Give documentation feedback