Advanced Settings for BMC Ethernet
Use this menu to configure advanced BMC Ethernet settings.
Item | Operation | Description |
---|---|---|
Advanced Settings for BMC Ethernet | ||
Autonegotiation |
| Selectable option. Choose whether the Data rate and Duplex network settings are configurable or not. Yes is the default setting. |
Data rate | Autonegotiation is ‘Yes’: Auto Autonegotiation is ‘No’: 100 Mb (Ethernet) 10 Mb (Ethernet) | Selectable option. Set amount of data to be transferred per second over LAN connection. Yes is the default setting. |
Duplex | Autonegotiation is ‘Yes’: Auto Autonegotiation is ‘No’: Half Full | Selectable option. Type of communication channel used in your network. [Full]: Allow data to be transferred in both directions at once. [Half]: Allow data to be transferred in either one direction or the other, but not both at the same time. Yes is the default setting. |
Maximum Transmission Unit | 1500 | Numeric input. Specify the maximum size of a packet (in bytes) for the network interface. The valid range is 68 – 1500. 1500 is the default setting. |