Single node cannot ping the management node in a different chassis

Use the information in this section to troubleshoot a single Flex System x222 Compute Node that cannot ping the Flex System Manager management node in a different chassis on the management network.

Complete the following steps until the problem is solved:
  1. Make sure that the management node is powered on and is not hung, by logging in to the management node. If you are unable to log in from the management network, attempt to log in from the data network. If the management node is powered on and hung, perform a virtual reseat of the management node from the CMM.
  2. Make sure that the CMM is powered on and is not hung, by pinging the CMM from the management node:
    1. If the CMM is powered on and hung, reset the CMM
    2. Make sure that the Flex System x222 Compute Node IMMs, the management node, and CMM are all on the same subnet.
  3. Make sure that the upper and lower compute nodes in the Flex System x222 Compute Node are the only ones in the chassis that the management node cannot ping. If it is not, follow the steps in Multiple nodes cannot ping the management node in the same chassis. Make sure that the compute nodes appear on the chassis map (it might not be fully discovered by the management node software).
  4. Make sure that the IMMs have acquired IP addresses from the CMM by using the Setup utility on the compute nodes.
    Note
    If the CMM recently lost connection to the DCHP server, you must reset the IMMs by using the CMM interface so that new IP addresses can be acquired.
  5. Make sure that the system-management processor in each compute node has a valid IP address by checking the chassis map of the remote chassis.
    Note
    If the CMM recently lost connection to the DCHP server, you must reset the IMMs by using the CMM interface so that new IP addresses can be acquired.
  6. Check the Lenovo Support Portal for any firmware updates that might apply to this issue. You can view the release notes for a firmware update to determine the issues that are addressed by the update.
  7. Check the Lenovo Support Portal for any service bulletins that are related to network connectivity.
  8. Remove the Flex System x222 Compute Node and make sure that the connectors on the midplane and the node are not damaged.
  9. (Trained service technician only) Check the connectors on the compute node and the chassis midplane to make sure that no pins are bent.