Test results for the DSA checkpoint panel test

The following messages can result when you run the DSA checkpoint panel test.

  • 180-000-000 : Check-point Panel Test Passed

    Check-point Panel Test Passed.
    Recoverable
    No
    Severity
    Event
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 180-801-000 : Check-point Panel Test Aborted

    Check-point Panel Test Aborted. BMC is unable to verify that the operator information panel cable is connected.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Complete the following steps:
    1. Inspect and reseat operator information panel cable at both ends.
    2. Verify that the Baseboard Management Controller (BMC) is working.
    3. Run the test again.
    4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links
  • 180-901-000 : Check-point Panel Test Failed

    Check-point Panel Test Failed. Operator reported incorrect display.
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Complete the following steps:
    1. Check the operator information panel cabling for loose or broken connections at both ends or damage to the cable.
    2. Replace the information panel cable if damage is present.
    3. Run the test again.
    4. Replace the operator information panel assembly.
    5. Run the test again.
    6. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links