Skip to main content

Test results for the DSA Emulex adapter test

The following messages can result when you run the DSA Emulex adapter test.

  • 516-000-000 : ELXUCNA: NIC MAC LoopBackTest Passed

    The test passed.
    Recoverable
    No
    Severity
    Event
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 516-001-000 : ELXUCNA: NIC PHY LoopBackTest Passed

    The test passed.
    Recoverable
    No
    Severity
    Event
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 516-002-000 : ELXUCNA: ELXUCNA: NIC LED(Beacon)Test Passed

    The test passed.
    Recoverable
    No
    Severity
    Event
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 516-800-000 : ELXUCNA: NIC MAC LoopBackTest Aborted

    Loopback testing at the MAC layer was canceled.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 516-801-000 : ELXUCNA: NIC PHY LoopBackTest Aborted

    Loopback testing at the physical layer was canceled.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 516-802-000 : ELXUCNA: ELXUCNA: NIC LED(Beacon)Test Aborted

    Verification of status LEDs was canceled.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 516-900-000 : ELXUCNA: NIC MAC LoopBackTest Failed

    A failure was detected during the loopback test at the MAC layer.
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Complete the following steps:
    1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
    2. Rerun the test.
    3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links
  • 516-901-000 : ELXUCNA: NIC PHY LoopBackTest Failed

    A failure was detected during the loopback test at the physical layer.
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Complete the following steps:
    1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
    2. Rerun the test.
    3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links
  • 516-902-000 : ELXUCNA: ELXUCNA: NIC LED(Beacon)Test Failed

    A failure was detected while verifying operation of the status LEDs.
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Complete the following steps:
    1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
    2. Rerun the test.
    3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links