Test results for the DSA memory isolation test
The following messages can result when you run the DSA memory isolation test.
201-000-000 : Standalone Memory Test Passed
Quick/Full Memory Test All CPUs Passed.- Recoverable
- No
- Severity
- Event
- Serviceable
- No
- Automatically notify support
- No
- Related links
201-000-001 : Standalone Memory Test Passed
Quick/Full Memory Test CPU 1 Passed.- Recoverable
- No
- Severity
- Event
- Serviceable
- No
- Automatically notify support
- No
- Related links
201-000-002 : Standalone Memory Test Passed
Quick/Full Memory Test CPU 2 Passed.- Recoverable
- No
- Severity
- Event
- Serviceable
- No
- Automatically notify support
- No
- Related links
201-000-003 : Standalone Memory Test Passed
Quick/Full Memory Test CPU 3 Passed.- Recoverable
- No
- Severity
- Event
- Serviceable
- No
- Automatically notify support
- No
- Related links
201-000-004 : Standalone Memory Test Passed
Quick/Full Memory Test CPU 4 Passed.- Recoverable
- No
- Severity
- Event
- Serviceable
- No
- Automatically notify support
- No
- Related links
201-811-000 : Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-811-001 : Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-811-002 : Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-811-003 : Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-812-000 : Standalone Memory Test Aborted
Memory test is not supported for this system.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-812-001 : Standalone Memory Test Aborted
Memory test is not supported for this system.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-812-002 : Standalone Memory Test Aborted
Memory test is not supported for this system.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-812-003 : Standalone Memory Test Aborted
Memory test is not supported for this system.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-813-000 : Standalone Memory Test Aborted
Chipset Error: Can not turn OFF ECC error reporting in CPU.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-813-001 : Standalone Memory Test Aborted
Chipset Error: Can not turn OFF ECC error reporting in CPU.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-813-002 : Standalone Memory Test Aborted
Chipset Error: Can not turn OFF ECC error reporting in CPU.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-813-003 : Standalone Memory Test Aborted
Chipset Error: Can not turn OFF ECC error reporting in CPU.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-814-000 : Standalone Memory Test Aborted
Chipset Error: Can not disable Scubbing feature for CPU.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-814-001 : Standalone Memory Test Aborted
Chipset Error: Can not disable Scubbing feature for CPU.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-814-002 : Standalone Memory Test Aborted
Chipset Error: Can not disable Scubbing feature for CPU.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-814-003 : Standalone Memory Test Aborted
Chipset Error: Can not disable Scubbing feature for CPU.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-815-000 : Standalone Memory Test Aborted
Program Error with Quick Memory Menu Option Selection.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-815-001 : Standalone Memory Test Aborted
Program Error with Quick Memory Menu Option Selection.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-815-002 : Standalone Memory Test Aborted
Program Error with Quick Memory Menu Option Selection.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-815-003 : Standalone Memory Test Aborted
Program Error with Quick Memory Menu Option Selection.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-816-000 : Standalone Memory Test Aborted
Program Error with Full Memory Menu Option Selection.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-816-001 : Standalone Memory Test Aborted
Program Error with Full Memory Menu Option Selection.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-816-002 : Standalone Memory Test Aborted
Program Error with Full Memory Menu Option Selection.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-816-003 : Standalone Memory Test Aborted
Program Error with Full Memory Menu Option Selection.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-818-000 : Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-818-001 : Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-818-002 : Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-818-003 : Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-819-000 : Standalone Memory Test Aborted
The start-end address ranges in the restricted area of the memory.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-819-001 : Standalone Memory Test Aborted
The start-end address ranges in the restricted area of the memory.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-819-002 : Standalone Memory Test Aborted
The start-end address ranges in the restricted area of the memory.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-819-003 : Standalone Memory Test Aborted
The start-end address ranges in the restricted area of the memory.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-820-000 : Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-820-001 : Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-820-002 : Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-820-003 : Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-821-000 : Standalone Memory Test Aborted
Variable range MTRR registers are larger than fixed range MTRR registers.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-821-001 : Standalone Memory Test Aborted
Variable range MTRR registers are larger than fixed range MTRR registers.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-821-002 : Standalone Memory Test Aborted
Variable range MTRR registers are larger than fixed range MTRR registers.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-821-003 : Standalone Memory Test Aborted
Variable range MTRR registers are larger than fixed range MTRR registers.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-822-000 : Standalone Memory Test Aborted
Invalid MTRR service request.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-822-001 : Standalone Memory Test Aborted
Invalid MTRR service request.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-822-002 : Standalone Memory Test Aborted
Invalid MTRR service request.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-822-003 : Standalone Memory Test Aborted
Invalid MTRR service request.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-824-000 : Standalone Memory Test Aborted
Node Interleave feature must be OFF. Go to Setup and disable Node Interleave option and then re-run the test.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-824-001 : Standalone Memory Test Aborted
Node Interleave feature must be OFF. Go to Setup and disable Node Interleave option and then re-run the test.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-824-002 : Standalone Memory Test Aborted
Node Interleave feature must be OFF. Go to Setup and disable Node Interleave option and then re-run the test.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-824-003 : Standalone Memory Test Aborted
Node Interleave feature must be OFF. Go to Setup and disable Node Interleave option and then re-run the test.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-826-000 : Standalone Memory Test Aborted
BIOS: Memory Controller has been disabled. Go to Setup and Enable Memory Controller.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-826-001 : Standalone Memory Test Aborted
BIOS: Memory Controller has been disabled. Go to Setup and Enable Memory Controller.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-826-002 : Standalone Memory Test Aborted
BIOS: Memory Controller has been disabled. Go to Setup and Enable Memory Controller.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-826-003 : Standalone Memory Test Aborted
BIOS: Memory Controller has been disabled. Go to Setup and Enable Memory Controller.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-827-000 : Standalone Memory Test Aborted
BIOS: ECC function has been disabled by BIOS. Go to Setup and enable ECC generation.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-827-001 : Standalone Memory Test Aborted
BIOS: ECC function has been disabled by BIOS. Go to Setup and enable ECC generation.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-827-002 : Standalone Memory Test Aborted
BIOS: ECC function has been disabled by BIOS. Go to Setup and enable ECC generation.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-827-003 : Standalone Memory Test Aborted
BIOS: ECC function has been disabled by BIOS. Go to Setup and enable ECC generation.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-844-000 : Standalone Memory Test Aborted
Chipset Error: Problem in masking MSR machine check control MASK registers.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-844-001 : Standalone Memory Test Aborted
Chipset Error: Problem in masking MSR machine check control MASK registers.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-844-002 : Standalone Memory Test Aborted
Chipset Error: Problem in masking MSR machine check control MASK registers.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-844-003 : Standalone Memory Test Aborted
Chipset Error: Problem in masking MSR machine check control MASK registers.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-845-000 : Standalone Memory Test Aborted
Chipset Error: Problem clearing MSR machine check control registers.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-845-001 : Standalone Memory Test Aborted
Chipset Error: Problem clearing MSR machine check control registers.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-845-002 : Standalone Memory Test Aborted
Chipset Error: Problem clearing MSR machine check control registers.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-845-003 : Standalone Memory Test Aborted
Chipset Error: Problem clearing MSR machine check control registers.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-859-000 : Standalone Memory Test Aborted
INVALID XSECSRAT type.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-859-001 : Standalone Memory Test Aborted
INVALID XSECSRAT type.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-859-002 : Standalone Memory Test Aborted
INVALID XSECSRAT type.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-859-003 : Standalone Memory Test Aborted
INVALID XSECSRAT type.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-860-000 : Standalone Memory Test Aborted
No OEM0 type 1 found.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-860-001 : Standalone Memory Test Aborted
No OEM0 type 1 found.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-860-002 : Standalone Memory Test Aborted
No OEM0 type 1 found.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-860-003 : Standalone Memory Test Aborted
No OEM0 type 1 found.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-861-000 : Standalone Memory Test Aborted
No SRAT type 1 found.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-861-001 : Standalone Memory Test Aborted
No SRAT type 1 found.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-861-002 : Standalone Memory Test Aborted
No SRAT type 1 found.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-861-003 : Standalone Memory Test Aborted
No SRAT type 1 found.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-862-000 : Standalone Memory Test Aborted
No OEM1 structure found.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-862-001 : Standalone Memory Test Aborted
No OEM1 structure found.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-862-002 : Standalone Memory Test Aborted
No OEM1 structure found.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-862-003 : Standalone Memory Test Aborted
No OEM1 structure found.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-863-000 : Standalone Memory Test Aborted
No IBMERROR key in OEM1 structure.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-863-001 : Standalone Memory Test Aborted
No IBMERROR key in OEM1 structure.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-863-002 : Standalone Memory Test Aborted
No IBMERROR key in OEM1 structure.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-863-003 : Standalone Memory Test Aborted
No IBMERROR key in OEM1 structure.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-864-000 : Standalone Memory Test Aborted
No GAS located in OEM1.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-864-001 : Standalone Memory Test Aborted
No GAS located in OEM1.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-864-002 : Standalone Memory Test Aborted
No GAS located in OEM1.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-864-003 : Standalone Memory Test Aborted
No GAS located in OEM1.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-865-000 : Standalone Memory Test Aborted
No XSECSRAT key in OEM0 structure.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-865-001 : Standalone Memory Test Aborted
No XSECSRAT key in OEM0 structure.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-865-002 : Standalone Memory Test Aborted
No XSECSRAT key in OEM0 structure.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-865-003 : Standalone Memory Test Aborted
No XSECSRAT key in OEM0 structure.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-866-000 : Standalone Memory Test Aborted
EFI-SAL Invalid parameter from GetMemoryMap function.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-866-001 : Standalone Memory Test Aborted
EFI-SAL Invalid parameter from GetMemoryMap function.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-866-002 : Standalone Memory Test Aborted
EFI-SAL Invalid parameter from GetMemoryMap function.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-866-003 : Standalone Memory Test Aborted
EFI-SAL Invalid parameter from GetMemoryMap function.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-867-000 : Standalone Memory Test Aborted
EFI/SAL: Buffer not allocated.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-867-001 : Standalone Memory Test Aborted
EFI/SAL: Buffer not allocated.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-867-002 : Standalone Memory Test Aborted
EFI/SAL: Buffer not allocated.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-867-003 : Standalone Memory Test Aborted
EFI/SAL: Buffer not allocated.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-868-000 : Standalone Memory Test Aborted
EFI/SAL: Buffer allocated in GetMemoryMap too small.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-868-001 : Standalone Memory Test Aborted
EFI/SAL: Buffer allocated in GetMemoryMap too small.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-868-002 : Standalone Memory Test Aborted
EFI/SAL: Buffer allocated in GetMemoryMap too small.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-868-003 : Standalone Memory Test Aborted
EFI/SAL: Buffer allocated in GetMemoryMap too small.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-869-000 : Standalone Memory Test Aborted
EFI/SAL Invalid parameter from GetMemoryMap function.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-869-001 : Standalone Memory Test Aborted
EFI/SAL Invalid parameter from GetMemoryMap function.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-869-002 : Standalone Memory Test Aborted
EFI/SAL Invalid parameter from GetMemoryMap function.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-869-003 : Standalone Memory Test Aborted
EFI/SAL Invalid parameter from GetMemoryMap function.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-870-000 : Standalone Memory Test Aborted
CPU Doamin in ACPI not valid.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-870-001 : Standalone Memory Test Aborted
CPU Doamin in ACPI not valid.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-870-002 : Standalone Memory Test Aborted
CPU Doamin in ACPI not valid.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-870-003 : Standalone Memory Test Aborted
CPU Doamin in ACPI not valid.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-871-000 : Standalone Memory Test Aborted
Data Mis-compare encountered.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-871-001 : Standalone Memory Test Aborted
Data Mis-compare encountered.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-871-002 : Standalone Memory Test Aborted
Data Mis-compare encountered.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-871-003 : Standalone Memory Test Aborted
Data Mis-compare encountered.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-877-000 : Standalone Memory Test Aborted
BIOS: Sparing in Extended PCI reg. must be OFF. Go to setup and disable sparing.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-877-001 : Standalone Memory Test Aborted
BIOS: Sparing in Extended PCI reg. must be OFF. Go to setup and disable sparing.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-877-002 : Standalone Memory Test Aborted
BIOS: Sparing in Extended PCI reg. must be OFF. Go to setup and disable sparing.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-877-003 : Standalone Memory Test Aborted
BIOS: Sparing in Extended PCI reg. must be OFF. Go to setup and disable sparing.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-878-000 : Standalone Memory Test Aborted
Sparing feature must be turned OFF. Go to setup and turn the sparing feature OFF.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-878-001 : Standalone Memory Test Aborted
Sparing feature must be turned OFF. Go to setup and turn the sparing feature OFF.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-878-002 : Standalone Memory Test Aborted
Sparing feature must be turned OFF. Go to setup and turn the sparing feature OFF.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-878-003 : Standalone Memory Test Aborted
Sparing feature must be turned OFF. Go to setup and turn the sparing feature OFF.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-885-000 : Standalone Memory Test Aborted
Processor does not support MTRR register manipulation. Can not write to memory without cache.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-885-001 : Standalone Memory Test Aborted
Processor does not support MTRR register manipulation. Can not write to memory without cache.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-885-002 : Standalone Memory Test Aborted
Processor does not support MTRR register manipulation. Can not write to memory without cache.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-885-003 : Standalone Memory Test Aborted
Processor does not support MTRR register manipulation. Can not write to memory without cache.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-886-000 : Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-886-001 : Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-886-002 : Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-886-003 : Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
201-899-000 : Standalone Memory Test Aborted
Memory Diagnostics Test Aborted by user.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- Related links
201-899-001 : Standalone Memory Test Aborted
Memory Diagnostics Test Aborted by user.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- Related links
201-899-002 : Standalone Memory Test Aborted
Memory Diagnostics Test Aborted by user.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- Related links
201-899-003 : Standalone Memory Test Aborted
Memory Diagnostics Test Aborted by user.- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- Related links
201-901-000 : Standalone Memory Test Failed
Memory Diagnostics Test Failed.- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Replace any DIMMS(s) mentioned in error, one by one.
- Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
201-901-001 : Standalone Memory Test Failed
Memory Diagnostics Test Failed.- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Replace any DIMMS(s) mentioned in error, one by one.
- Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
201-901-002 : Standalone Memory Test Failed
Memory Diagnostics Test Failed.- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Replace any DIMMS(s) mentioned in error, one by one.
- Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
201-901-003 : Standalone Memory Test Failed
Memory Diagnostics Test Failed.- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Replace any DIMMS(s) mentioned in error, one by one.
- Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links