Server features and specifications
The following information is a summary of the features and specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.
Microprocessor (depending on the model):
Note
Fans:
| Memory:
| Drive:
Attention As a general consideration, do not mix standard 512-byte and advanced 4-KB format drives in the same RAID array because it might lead to potential performance issues. Note
Optional SATA optical drives:
|
RAID controllers:
Note
PCI and PCI-X expansion slots:
| Environment: The Lenovo System X3300 compute node complies with ASHRAE class A3 specifications.
| Heat output: Approximate heat output in British thermal units (Bts):
Integrated functions:
|
Power supply:
Video controller (integrated into IMM2):
| Electrical input:
| Acoustical noise emissions:
Chassis
|
Note
- The Lenovo System x3300 M4's tower-to-rack kit is required for the High IOPS MLC Mono adapter. The High IOPS MLC Mono adapter is only supported in the rack mount system.
- Power supplies in the server must be with the same power rating or wattage.
- Legacy 5V PCI adapters are not supported.
- When NVIDIA Quadro 600 graphics Adapter is supported, the max memory can’t exceed 128 GB.
- Graphic Card (VGA Card in SPP list) can only be installed for PCI Slot 4 with Full-Height bracket. It might be performance limited if VGA Card installed due to the elec. link is x8.
- Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.
- The sound levels were measured in controlled acoustical environments according to the procedures specified by ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The noise emission level stated in the declared (upper limit) sound-power level for a random sample of system.
When more than 2 PCI-e adapters have been installed on the system, it is necessary to follow the fan configuration instruction as the table below.
Table 2. Fan configuration instruction Fans Conditions 2 and Rear fan Standard for all systems 3 - When the second microprocessor is populated, the fan is included in the second microprocessor kit (P/N: 00D2581 ~ 00D2589). Or,
- When more than 2 PCI-e adapters have been installed on the system, the fan (P/N: 00D2593) must be populated separately.
1 Optional redundant fan (P/N: 00D2593). Attention16 GB 1.5V / 32 GB 1.35V DIMMs are installed, fan 1 must also be populated.
- EU Regulation 617/2013 Technical Documentation:
- International Business Machines Corporation
- New Orchard Road
- Armonk, New York 10504
- http://www.ibm.com/customersupport/
For more information on the energy efficiency program, go to http://www.ibm.com/systems/x/hardware/energy-star/index.html
- Product Type:
- Computer server
- Year first manufactured:
- 2012
- Internal/external power supply efficiency:
- http://www.plugloadsolutions.com/psu_reports/IBM_FSA011_550W_SO-301_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/IBM_7001605-XXXX_750W_SO-258_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/SO-299_IBM_DPS-750AB-1_750W_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/IBM_FSB013-030G_ECOS%203051_460W_Report.pdf
- Maximum power (watts):
- See Power supply.
- Idle state power (watts):
- 318
- Sleep mode power (watts):
- Not applicable for servers.
- Off mode power (watts):
- 21
- Noise levels (the declared A-weighed sound power level of the computer):
- See Acoustical noise emissions.
- Test voltage and frequency:
- 230V / 50 Hz or 60 Hz
- Total harmonic distortion of the electricity supply system:
- The maximum harmonic content of the input voltage waveform will be equal or less than 2%. The qualification is compliant with EN 61000-3-2.
- Information and documentation on the instrumentation set-up and circuits used for electrical testing:
- ENERGY STAR Test Method for Computer Servers; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies.
- Measurement methodology used to determine information in this document:
- ENERGY STAR Servers Version 2.0 Program Requirements; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies.
Give documentation feedback