Matrox G200eV (two analog ports - one front and one rear that can be connected at the same time)
Note
The maximum video resolution is 1600 x 1200 at 75 Hz.
SVGA compatible video controller
DDR2 250 MHz SDRAM video memory controller
Avocent Digital Video Compression
16 MB of video memory (not expandable)
Power supply:
Maximum of two hot-swap power supplies for redundancy support
460-watt ac
675-watt ac
675-watt high-efficiency ac
675-watt dc
Note
You cannot mix 460-watt and 675-watt power supplies, high-efficiency and non-high-efficiency power supplies, or ac and dc power supplies in the server.
Environment:
Air temperature:
Server on: 10°C to 35°C (50°F to 95°F); altitude: 0 to 914.4 m (3000 ft), decrease system temperature by 1.0°C for every 1000-foot increase in altitude
Server off: 5°C to 45°C (41°F to 113°F); maximum altitude: 3048 m (10000 ft)
Shipment: -40°C to 60°C (-40°F to 140°F); maximum altitude: 3048 m (10000 ft)
Humidity:
Server on: 20% to 80%; maximum dew point: 21°C; maximum rate of change: 5 °C/hr
Server off: 8% to 80%; maximum dew point: 27°C
Particulate contamination:
Attention
Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.
Heat output:
Approximate heat output:
Minimum configuration: 662 Btu per hour (194 watts)
Maximum configuration: 2302 Btu per hour (675 watts)
Integrated functions:
Integrated Management Module (IMM), which provides service processor control and monitoring functions, video controller, and (when the optional virtual media key is installed) remote keyboard, video, mouse, and remote hard disk drive capabilities
Broadcom BCM5709 Gb Ethernet controller with TCP/IP Offload Engine (TOE) and Wake on LAN support
Five Universal Serial Bus (USB) 2.0 ports (two front and two rear of the chassis, and one on the SAS/SATA RAID riser card in which the optional USB flash device with embedded hypervisor software is installed)
Four Ethernet ports (two on system board and two additional ports when the optional IBM Dual-Port 1 Gb Ethernet Daughter Card is installed)
One System Management RJ-45 on the rear to connect to a systems management network. This system management connector is dedicated to the IMM functions. This connector is active with or without the optional IBM Virtual Media Key installed.
One serial port
RAID controllers (depending on the model):
A ServeRAID-BR10il v2 SAS/SATA adapter that provides RAID levels 0, 1, and 1E (comes standard on some hot-swap models).
An optional ServeRAID-BR10i SAS/SATA adapter that provides RAID levels 0, 1, and 1E can be ordered.
An optional ServeRAID-MR10i SAS/SATA adapter that provides RAID levels 0, 1, 5, 6, 10, 50, and 60 can be ordered.
An optional ServerRAID M1015 SAS/SATA adapter that provides RAID levels 0, 1, and 10 with optional RAID 5/50 and SED (Self Encrypting Drive) upgrade.
An optional ServeRAID M5014 SAS/SATA adapter that provides RAID levels 0, 1, 5, 10 and 50 with optional RAID 6/60 and SED upgrade.
An optional ServeRAID M5015 SAS/SATA adapter that provides RAID levels 0, 1, 5, 10, and 50 with optional RAID 6/60 and SED upgrade.
Size:
1U
Height: 43 mm (1.7 inches)
Depth: 711 mm (28.0 inches)
Width: 440 mm (17.3 inches)
Weight: approximately 15.9 kg (35.1 lb) when fully configured
Acoustical noise emissions:
Sound power, idling: 6.1 bels maximum
Sound power, operating: 6.1 bels maximum
Electrical input:
Sine-wave input (47 - 63 Hz) required
Input voltage low range:
Minimum: 100 V ac
Maximum: 127 V ac
Input voltage high range:
Minimum: 200 V ac
Maximum: 240 V ac
Input kilovolt-amperes (kVA), approximately:
Minimum: 0.090 kVA
Maximum: 0.700 kVA
Note
Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.
The sound levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The noise emission level stated in the declared (upper limit) sound-power level, in bels, for a random sample of system.
Total harmonic distortion of the electricity supply system:
The maximum harmonic content of the input voltage waveform will be equal or less than 2%. The qualification is compliant with EN 61000-3-2.
Information and documentation on the instrumentation set-up and circuits used for electrical testing:
ENERGY STAR Test Method for Computer Servers; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies.
Measurement methodology used to determine information in this document:
ENERGY STAR Servers Version 2.0 Program Requirements; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies.