Light path diagnostics

Light path diagnostics is a system of LEDs on various external and internal components of the server that leads you to the failed component. When an error occurs, LEDs are lit along the path of the front panel, the light path diagnostics panel, then on the failed component. By viewing the LEDs in a particular order, you can often identify the source of the error.

When LEDs are lit to indicate an error, they remain lit when the server is turned off, provided that the server is still connected to power and the power supply is operating correctly.

Before you work inside the server to view light path diagnostics LEDs, read the safety information Safety and Handling static-sensitive devices.

If an error occurs, view the light path diagnostics LEDs in the following order:

  1. Look at the operator information panel on the front of the server.
    • If the check log LED is lit, it indicates that information about an un-isolated fault condition in the server is available in the IMM event log or in the system-event log.
    • If the system-error LED is lit, it indicates that an error has occurred; go to 2.
    The following illustration shows the operator information panel.
    Figure 1. Operator information panel
    Operator information panel
  2. To view the light path diagnostics panel, press the blue release latch on the operator information panel. Pull forward on the panel until the hinge of the operator information panel is free of the server chassis. Then pull down on the panel so that you can view the light path diagnostics panel information. This reveals the light path diagnostics panel. Lit LEDs on this panel indicate the type of error that has occurred.
    Figure 2. Light path diagnostics panel disengagement
    Light path diagnostics panel disengagement
    The following illustration shows the light path diagnostics panel.
    Figure 3. Light path diagnostics panel
    Light path diagnostics panel

    Note any LEDs that are lit, and then reinstall the light path diagnostics panel in the server.

    • Remind button: Press this button to place the system-error LED/check log LED on the front information panel into Remind mode. By placing the system-error LED indicator in Remind mode, you acknowledge that you are aware of the last failure but will not take immediate action to correct the problem. In Remind mode, the system-error LED flashes every 2 seconds until one of the following conditions occurs:
      • All known errors are corrected.
      • The server is restarted.
      • A new error occurs, causing the system-error LED to be lit again.
    • Reset button: Press this button to reset the server and run the power-on self-test (POST). You might have to use a pen or the end of a straightened paper clip to press the button. The Reset button is in the lower-right corner of the light path diagnostics panel.

    The system service label inside the server cover provides an overview of internal components that correspond to the LEDs on the light path diagnostics panel. This information and the information in Light path diagnostics LEDs can often provide enough information to diagnose the error.

  3. Remove the server cover and look inside the server for lit LEDs. Certain components inside the server have LEDs that are lit to indicate the location of a problem.
    Note
    You do not have to remove the server cover to view the LEDs on hard disk drives and power supplies.
    The following illustration shows the LEDs on the system board.
    Figure 4. System board error LEDs
    System board error LEDs