Server features and specifications
Use this information for an overview of the server features and specifications.
The following information is a summary of the features and specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.
- Microprocessor (depending on the model):
- Supports up to two multi-core microprocessors (one installed)
- Level-3 cache
- Two QuickPath Interconnect (QPI) links speed up to 8.0 GT per second
Note- Use the Setup utility to determine the type and speed of the microprocessors in the server
- For a list of supported microprocessors, see the Lenovo ServerProven website.
- Memory:
- Minimum: 2 GB
- Maximum: 768 GB
- 64 GB using unbuffered DIMMs (UDIMMs)
- 384 GB using registered DIMMs (RDIMMs)
- 768 GB using load reduction DIMMs (LRDIMMs)
- Type:
- PC3-8500 (DDR3-1066), PC3-10600 (DDR3-1333), PC3-12800 (DDR3-1600), or PC3-14900 (DDR3-1866)
- Single-rank, dual-rank, or quad-rank
- Unbuffered DIMM (UDIMM), registered DIMM (RDIMM), or load reduced DIMM (LRDIMM)
- Slots: 24 dual inline
- Supports (depending on the model):
- 4 GB UDIMM
- 2 GB, 4 GB, 8 GB, and 16 GB RDIMMs
- 32 GB LRDIMM
- Integrated functions:
- Integrated Management Module II (IMM2), which consolidates multiple management functions in a single chip.
- Intel I350AM4 Quad Port Gigabit Ethernet controller with Wake on LAN support
- Universal Serial Bus (USB) ports
- Front (optional): two ports (supported when the video and USB breakout cable is installed)
- Rear: four ports
- Internal: one port for Hypervisor USB key
- Six network ports (four 1 Gb Ethernet ports on the system board and two additional ports when the optional dual-port network adapter is installed)
- One System Management RJ-45 on the rear to connect to a systems management network. This system management connector is dedicated to the IMM2 functions.
- One serial port
- Two VGA ports. One is on the rear, the other one is optional when the video and USB breakout cable is installed
- Light path diagnostics panel
- Drive expansion bays (depending on the model):
- Sixteen 2.5-inch hot-swap SAS/SATA hard disk drive bays
- Add eight 2.5-inch hot-swap SAS/SATA hard disk drive bays (front); two 2.5-inch hot-swap SAS/SATA hard disk drive bays (rear)
- Add sixteen 1.8-inch solid state drive bays
AttentionAs a general consideration, do not mix standard 512-byte and advanced 4-KB format drives in the same RAID array because it might lead to potential performance issues.- Sixteen 2.5-inch hot-swap SAS/SATA hard disk drive bays
- PCI expansion slots (depending on your model):
- PCI riser-card assembly 1
- Type 1
- Slot 1: PCI Express 3.0 x8 (full-height, full-length)
- Slot 2: PCI Express 3.0 x8 (full-height, half-length)
- Slot 3: PCI Express 3.0 x8 (full-height, half-length)
- Type 2
- Slot 1: PCI Express 3.0 x16 (full-height, full-length)
- Slot 2: PCI Express 3.0 x8 (full-height, half-length)
- Slot 3 (not available)
- Type 3
- Slot 1: PCI-X (full-height, full-length)
- Slot 2: PCI-X (full-height, half-length)
- Slot 3: PCI Express 3.0 x16 (full-height, half-length)
- Type 4
- Slot 1 (not available)
- Slot 2: PCI Express 3.0 x16 (full-height, half-length)
- Slot 3: PCI Express 3.0 x8 (full-height, half-length)
- Type 1
- Slot 4: PCI Express 3.0 x8 (full-height, full-length)
- Slot 5: PCI Express 3.0 x8 (full-height, full-length)
- Slot 6: PCI Express 3.0 x8 (full-height, half-length)
- Type 2
- Slot 4: PCI Express 3.0 x16 (full-height, full-length)
- Slot 5: PCI Express 3.0 x8 (full-height, full-length)
- Slot 6 (not available)
- Type 3
- Slot 4: PCI-X (full-height, full-length)
- Slot 5: PCI-X (full-height, full-length)
- Slot 6: PCI Express 3.0 x16 (full-height, half-length)
- Type 4
- Slot 4 (not available)
- Slot 5: PCI Express 3.0 x16 (full-height, full-length)
- Slot 6: PCI Express 3.0 x8 (full-height, half-length)
- Type 1
- Power supply:
- Up to two hot-swap power supplies for redundancy support
- 550-watt ac
- 750-watt ac
- 750-watt dc
- 900-watt ac
Note- Power supplies in the server must be with the same power rating or wattage.
- Up to two hot-swap power supplies for redundancy support
- Hot-swap fans:
The server supports 4 hot-swap fans.
- RAID controllers (depending on the model):
- Supported on-board RAID controllers:
- ServeRAID M5210e
- Integrated functions:
- Integrated Management Module II (IMM2), which consolidates multiple management functions in a single chip.
- Intel I350AM4 Quad Port Gigabit Ethernet controller with Wake on LAN support
- Universal Serial Bus (USB) ports
- Front (optional): two ports (supported when the video and USB breakout cable is installed)
- Rear: four ports
- Internal: one port for Hypervisor USB key
- Six network ports (four 1 Gb Ethernet ports on the system board and two additional ports when the optional dual-port network adapter is installed)
- One System Management RJ-45 on the rear to connect to a systems management network. This system management connector is dedicated to the IMM2 functions.
- One serial port
- Two VGA ports. One is on the rear, the other one is optional when the video and USB breakout cable is installed
- Light path diagnostics panel
- Video controller (integrated into the IMM2):
- Matrox G200eR core (two analog ports: one front and one rear that can be connected at the same time)NoteThe maximum video resolution is 1600 x 1200 at 75 Hz.
- SVGA compatible video controller
- DDR3 528 MHz SDRAM video memory controller
- Avocent Digital Video Compression
- 16 MB of video memory (not expandable)
- Matrox G200eR core (two analog ports: one front and one rear that can be connected at the same time)
- Size (2U):
- Height: 86.5 mm (3.406 in.)
- Depth: EIA flange to rear - 714 mm (28.110 in.), Overall - 746 mm (29.370 in.)
- Width: With top cover - 445 mm (17.520 in.), With front bezel - 482.0 mm (18.976 in.)
- Weight: approximately 25 kg (55 lb) to 30 kg (65 lb) depending upon configuration
- Acoustical noise emissions:
- Sound power, idling: 6.3 bels maximum
- Sound power, operating: 7.0 bels maximum
- Environment:
- Server on
- Maximum altitude: 3,050 m (10,000 ft), 5°C to 28°C (41°F to 82°F)Attention
- Design to ASHRAE Class A3, Temperature: 36°C - 40°C (96.8°F - 104°F) with relaxed support:
- Support cloud like workload with no performance degradation acceptable (Turbo-Off).
- Under no circumstance, can any combination of worst case workload and configuration result in system shutdown or design exposure at 40°C.
- The worst case workload (such as Linpack, Turbo-On) may have performance degradation.
- Design to ASHRAE Class A3, Temperature: 36°C - 40°C (96.8°F - 104°F) with relaxed support:
- Temperature:
- 5°C to 40°C (41°F to 104°F)
- Altitude: 0 to 950 m (3,117 ft); decrease the maximum system temperature by 1°C for every 175-m increase in altitude.
- Humidity:
- Non-condensing: -12°C dew point (10.4°F)
- Relative humidity: 8% to 85%
- Maximum dew point: 24°C (75°F)
- Maximum rate of temperature change:
- Hard disk drives: 20°C/hr (68°F/hr)
- Maximum altitude: 3,050 m (10,000 ft), 5°C to 28°C (41°F to 82°F)
- Environment:
- Server off:
- Temperature: 5°C to 45°C (41°F to 113°F)
- Relative humidity: 8% to 85%
- Maximum dew point: 27°C (80.6°F)
Storage (non-operating):- Temperature: 1°C to 60°C (33.8°F to 140.0°F)
- Maximum altitude: 3,050 m (10,000 ft)
- Relative humidity: 5% to 80%
- Maximum dew point: 29°C (84.2°F)
Shipment (non-operating):- Temperature: -40°C to 60°C (-40°F to 140.0°F)
- Maximum altitude: 10,700 m (35,105 ft)
- Relative humidity: 5% to 100%
- Maximum dew point: 29°C (84.2°F)
Particulate contamination: airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.
- Heat output:
- Approximate heat output:
- Minimum configuration: 419.68 Btu per hour (AC 123 watts)
- Maximum configuration: 4053 Btu per hour (AC 1188 watts)
- Electrical input:
- Sine-wave input (50 - 60 Hz) required
- Input voltage low range:
- Minimum: 100 V ac
- Maximum: 127 V ac
- Input voltage high range:
- Minimum: 200 V ac
- Maximum: 240 V ac
- Input kilovolt-amperes (kVA), approximately:
- Minimum: 0.14 kVA
- Maximum: 1.201 kVA
- Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.
- The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random sample of machines. All measurements are made in accordance with ISO 7779 and reported in conformance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The noise emission level stated in the declared (upper limit) sound-power level, in bels, for a random sample of system.
One or two 550-watt power supplies | One 750-watt power supply | Two 750-watt power supplies | One 900-watt power supply | Two 900-watt power supplies | |||
---|---|---|---|---|---|---|---|
Video adapters | Not supported | Not supported | Quadro K600 or K2000 | Two Quadro K600 or K2000 | Not supported | Quadro K600 or K2000 | Two Quadro K600 or K2000 |
Microprocessor | Support up to 95-watt | Support up to 115-watt | |||||
Maximum amount of DIMMs | 8 (LRDIMM not supported) | 16 for UDIMM and RDIMM 8 for LRDIMM | 16 for UDIMM and RDIMM 8 for LRDIMM | 16 (LRDIMM not supported) | 24 (LRDIMM not supported) | 24 (LRDIMM not supported) | |
Maximum amount of PCI adapters | 2 | 1 | 1 | 1 | 3 | 1 | 2 |
Maximum amount of 2.5-inch HDDs | 16 | 26 | 26 | 26 | 26 | 26 | 16 |
Note
|
System with no GPU | System with one K2000 | System with two K2000 | |
---|---|---|---|
Microprocessor | E5-2637V2, E5-2643V2, E5-2667V2 | E5-2637V2, E5-2643V2, E5-2667V2 | E5-2637V2, E5-2643V2, E5-2667V2 |
Temperature | 5°C to 30°C (41°F to 85°F) | 5°C to 30°C (41°F to 85°F) | 5°C to 25°C (41°F to 77°F) |
Altitude | 0 to 304.8m (0 to 1,000 ft) | 0 to 304.8m (0 to 1,000 ft) | 0 to 304.8m (0 to 1,000 ft) |
Note
|
- EU Regulation 617/2013 Technical Documentation:
- International Business Machines Corporation
- New Orchard Road
- Armonk, New York 10504
- http://www.ibm.com/customersupport/
For more information on the energy efficiency program, go to http://www.ibm.com/systems/x/hardware/energy-star/index.html
- Product Type:
- Computer server
- Year first manufactured:
- 2013
- Internal/external power supply efficiency:
- http://www.plugloadsolutions.com/psu_reports/IBM_FSA011_550W_SO-301_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/IBM_7001676-XXXX_550W_SO-458_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/IBM_7001605-XXXX_750W_SO-258_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/SO-299_IBM_DPS-750AB-1_750W_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/IBM_DPS-750AB-14%20A_750W_SO-527_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/IBM_7001606-XXXX_900W_SO-273_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/IBM_DPS-900CB%20A_900W_SO-440_Report.pdf
- Maximum power (watts):
- See Power supply.
- Idle state power (watts):
- 272
- Sleep mode power (watts):
- Not applicable for servers.
- Off mode power (watts):
- 16
- Noise levels (the declared A-weighed sound power level of the computer):
- See Acoustical noise emissions.
- Test voltage and frequency:
- 230V / 50 Hz or 60 Hz
- Total harmonic distortion of the electricity supply system:
- The maximum harmonic content of the input voltage waveform will be equal or less than 2%. The qualification is compliant with EN 61000-3-2.
- Information and documentation on the instrumentation set-up and circuits used for electrical testing:
- ENERGY STAR Test Method for Computer Servers; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies.
- Measurement methodology used to determine information in this document:
- ENERGY STAR Servers Version 2.0 Program Requirements; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies.