Skip to main content

Boot code display error codes

Use this information to resolve boot code error messages.

The boot code display area of the light path diagnostics panel provides an error code that indicates the point at which the system stopped during the boot block and POST. A boot code is either a byte or a word value that is produced by UEFI. This display will provide error codes in the event of a microprocessor error or a power fault. In addition to the IMM log, the codes can provide suggested components to be replaced.

The following is an illustration show the boot code display area on the light path diagnostics panel:

The following table lists the error codes that might display in the boot code display area that is associated with the integrated voltage regulator power faults or microprocessor failure events. Follow the action plan listed for the corresponding IMM events listed in this table to solve the problem. See the Integrated management module II (IMM2) error messages for the corresponding IMM event ID and action plan to follow and correct the problem.

Table 1. System power faults.

Boot codeMessagePotential defective componentCorresponding IMM Event IDCorresponding IMM log message
015V_PGOODSystem Board80070603-0701ffffSensor System VRD has transitioned to non-recoverable.
020_8VAUX_PGOOD10G-T Card80070603-0B01ffffSensor 10Gb-T VRD has transitioned to non-recoverable.
03ENET_1_0VAUX_PGOODSystem Board80070603-0701ffffSensor 10Gb-T VRD has transitioned to non-recoverable.
041_1V_PGOODSystem Board80070603-0701ffffSensor MainBrd VRD has transitioned to non-recoverable.
051_2VAUX_PGOODSystem Board80070603-0701ffffSensor MainBrd VRD has transitioned to non-recoverable.
061_25VAUX_PGOODSystem Board80070603-0701ffffSensor MainBrd VRD has transitioned to non-recoverable.
071_5VAUX_PGOODSystem Board80070603-0701ffffSensor MainBrd VRD has transitioned to non-recoverable.
08ENET_1_8VAUX_PGOODSystem Board80070603-0701ffffSensor MainBrd ENET VRD has transitioned to non-recoverable.
09ENET_2_5VAUX_PGOODSystem Board80070603-0701ffffSensor MainBrd ENET VRD has transitioned to non-recoverable.
0A3_3VAUX_PGOODSystem Board80070603-0701ffffSensor System VRD has transitioned to non-recoverable.
0B5VAUX_PGOODSystem Board80070603-0701ffffSensor System VRD has transitioned to non-recoverable.
0C2_5VAUX_PGOODSystem Board80070603-0701ffffSensor MainBrd VRD has transitioned to non-recoverable.
0DPS_12V_PGOODSystem Board80070603-2584ffffSensor Power Supply has transitioned to non-recoverable.
0EPCH_1_5V_PGOODSystem Board80070603-0701ffffSensor MainBrd VRD has transitioned to non-recoverable.
0FSAS_0_75V_PGOODSystem Board80070603-0701ffffSensor MainBrd SAS VRD has transitioned to non-recoverable.
10SAS_1_0V_PGOODSystem Board80070603-0701ffffSensor MainBrd SAS VRD has transitioned to non-recoverable.
11SAS_AVSO_PGOODSystem Board80070603-0701ffffSensor MainBrd SAS VRD has transitioned to non-recoverable.
12SAS_1_5V_PGOODSystem Board80070603-0701ffffSensor MainBrd SAS VRD has transitioned to non-recoverable.
13SAS_1_8V_PGOODSystem Board80070603-0701ffffSensor MainBrd SAS VRD has transitioned to non-recoverable.
143_3V_PGOODSystem Board80070603-0701ffffSensor System VRD has transitioned to non-recoverable.
16ENET_1_5VAUX_PGOODSystem Board80070603-0701ffffSensor MainBrd ENET VRD has transitioned to non-recoverable.
17DIMM_3_3VAUX_PGOODSystem Board80070603-0701ffffSensor MainBrd VRD has transitioned to non-recoverable.
18MEM1A_VDDQ_PGOODSystem Board80070603-0701ffffSensor DIMM 1-6 VRD has transitioned to non-recoverable.
19MEM1B_VDDQ_PGOODSystem Board80070603-0701ffffSensor DIMM 7-12 VRD has transitioned to non-recoverable.
1AMEM2A_VDDQ_PGOODSystem Board80070603-0701ffffSensor DIMM 13-18 VRD has transitioned to non-recoverable.
1BMEM2B_VDDQ_PGOODSystem Board80070603-0701ffffSensor DIMM 19-24 VRD has transitioned to non-recoverable.
1CMEM3A_VDDQ_PGOODCPU/Memory Tray80070603-2B01ffffSensor DIMM 25-30 VRD has transitioned to non-recoverable.
1DMEM3B_VDDQ_PGOODCPU/Memory Tray80070603-2B01ffffSensor DIMM 31-36 VRD has transitioned to non-recoverable.
1EMEM4A_VDDQ_PGOODCPU/Memory Tray80070603-2B01ffffSensor DIMM 37-42 VRD has transitioned to non-recoverable.
1FMEM4B_VDDQ_PGOODCPU/Memory Tray80070603-2B01ffffSensor DIMM 43-48 VRD has transitioned to non-recoverable.
20OC_FAULTSystem Board80070603-0701ffffSensor System VRD has transitioned to non-recoverable.
28CPU1_VCORE_PGOODSystem Board80070603-0701ffffSensor CPU1 VRD has transitioned to non-recoverable.
29CPU2_VCORE_PGOODSystem Board80070603-0701ffffSensor CPU2 VRD has transitioned to non-recoverable.
2ACPU3_VCORE_PGOODCPU/Memory Tray80070603-2B01ffffSensor CPU3 VRD has transitioned to non-recoverable.
2BCPU4_VCORE_PGOODCPU/Memory Tray80070603-2B01ffffSensor CPU4 VRD has transitioned to non-recoverable.
2CCPU1_VPLL_PGOODSystem Board80070603-0701ffffSensor CPU1 VRD has transitioned to non-recoverable.
2DCPU2_VPLL_PGOODSystem Board80070603-0701ffffSensor CPU2 VRD has transitioned to non-recoverable.
2ECPU3_VPLL_PGOODCPU/Memory Tray80070603-2B01ffffSensor CPU3 VRD has transitioned to non-recoverable.
2FCPU4_VPLL_PGOODCPU/Memory Tray80070603-2B01ffffSensor CPU4 VRD has transitioned to non-recoverable.
30CPU1_VSA_PGOODSystem Board80070603-0701ffffSensor CPU1 VRD has transitioned to non-recoverable.
31CPU2_VSA_PGOODSystem Board80070603-0701ffffSensor CPU2 VRD has transitioned to non-recoverable.
32CPU3_VSA_PGOODCPU/Memory Tray80070603-2B01ffffSensor CPU3 VRD has transitioned to non-recoverable.
33CPU4_VSA_PGOODCPU/Memory Tray80070603-2B01ffffSensor CPU4 VRD has transitioned to non-recoverable.
34CPU1_VTT_PGOODSystem Board80070603-0701ffffSensor CPU1 VRD has transitioned to non-recoverable.
35CPU2_VTT_PGOODSystem Board80070603-0701ffffSensor CPU2 VRD has transitioned to non-recoverable.
36CPU3_VTT_PGOODCPU/Memory Tray80070603-2B01ffffSensor CPU3 VRD has transitioned to non-recoverable.
37CPU4_VTT_PGOODCPU/Memory Tray80070603-2B01ffffSensor CPU4 VRD has transitioned to non-recoverable.
3EENET_1_2VAUX_PGOODSystem Board80070603-0701ffffSensor MainBrd ENET VRD has transitioned to non-recoverable.
3FFPGA_CPU1_VTTAUX_PGOODSystem Board80070603-0701ffffSensor MainBrd VRD has transitioned to non-recoverable.