Locally: LAN over USB
If you omit any optional parameter, the default value is used. If one or more default values are used and the ASU cannot access the IMM2 by using the LAN over USB access method, the ASU automatically uses the KCS access method.
To update the UUID, in the ASU command-line interface, enter the following command:
Note
If you omit any optional parameter, the default value is used. If one or more default values are used and the ASU cannot access the IMM by using the LAN over USB access method, the ASU automatically uses the KCS access method.
asu set SYSTEM_PROD_DATA.SysInfoUUID uuid [--host ipaddress] [--user userid][--password password]
where:
- uuid
- is the user-assigned hexadecimal value, up to 16 bytes, that identifies the server.
- ipaddress
- is the internal LAN/USB IP address of the IMM. The default is 169.254.95.118.
- userid
- is the IMM account name (1 of 12 accounts). The default is USERID.
- password
- is the IMM account password (1 of 12 accounts). The default is PASSW0RD (with a zero, not the letter O).
To update the DMI/SMBIOS data, complete the following steps:
Give documentation feedback