BMC self tests
Use this information to resolve BMC self-test errors by referencing the error codes and following the suggested corrective actions.
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
| ||
---|---|---|
Error code | Description | Action |
166-901-xxx | Failed the BMC test due to a failure in the host bus. |
|
166-902-xxx | Failed the BMC self test due to a failure in SIO Bus and DASD SEP. |
|
166-903-xxx | Failed the BMC self test due to a failure in the LAN or cKVM bus. |
|
166-904-xxx | Failed the BMC self test due to a failure in the main expander. |
|
166-905-xxx | Failed the BMC self test due to a failure in the CPU/VRD bus. | Note Ignore this error if the direct access storage device (DASD) planar is not installed.
|
166-906-xxx | Failed the BMC self test due to a failure in VPD or Power PSOC. |
|
166-907-xxx | Failed the BMC self test due to a failure in the EXP A0 bus. |
|
166-908-xxx | Failed the BMC self test due to a failure in the EXP A1 bus. |
|
166-909-xxx | Failed the BMC self test due to a failure in the EXP B bus. |
|
166-910-xxx | Failed the BMC self test due to a failure in the onboard legacy daughter card. |
|
166-911-xxx | Failed the BMC self test due to a failure in the BSE-3 PCI-X A slot. |
|
166-912-xxx | Failed the BMC self test due to a failure in the BSE-3 PCI-X B slot. |
|
Give documentation feedback