Microprocessor: Up to 2 multi-core IntelXeon processors. Use the Setup utility to determine the type and speed of the microprocessors in the blade server. Memory:- 16 dual inline memory module (DIMM) connectors
- Type: Very Low Profile (VLP) double-data rate (DDR3) DRAM. Supports 2 GB, 4 GB, 8 GB, 16 GB, and 32 GB DIMMs with up to 512 GB of total memory on the system board
If two BladeCenter HX5 blade servers are assembled into a scalable blade complex, up to 1 TB is available to the scalable blade complex. If the IBM MAX5 is installed: - Supports up to 40 dual inline memory module (DIMM) connectors for up to 1.25 TB of total memory.
The BladeCenter HX5 blade server supports memory sparing. Integrated functions:- Horizontal-compact-form-factor (CFFh) expansion card interface
- Vertical-combination-I/O (CIOv) expansion card interface
- Local service processor: integrated management module (IMM) with Intelligent Platform Management Interface (IPMI) firmware
- Integrated Matrox G200eV video controller
| - Broadcom BCM5709S dual-port Gigabit Ethernet controller
- Integrated keyboard/video/mouse (cKVM) controller through IMM
- Light path diagnostics
- RS-485 interface for communication with the management module
- Automatic server restart (ASR)
- USB 2.0 for communication with cKVM and removable media drives (an external USB port is not supported)
- Serial over LAN (SOL)
- Wake on LAN (WOL)
- Redundant buses for communication with keyboard, mouse, and removable media drives
Predictive Failure Analysis (PFA) alerts: Electrical input: 12 V dc Size: Single BladeCenter HX5 blade server: - Height: 24.5 cm (9.7 in) (6U)
- Depth: 44.6 cm (17.6 in)
- Width: 2.9 cm (1.14 in)
- Maximum weight: 5.6 kg (12.38 lb)
2 BladeCenter HX5 blade servers assembled into a scalable blade complex: - Height: 24.5 cm (9.7 in) (6U)
- Depth: 44.6 cm (17.6 in)
- Width: 5.8 cm (2.28 in)
- Maximum weight: 11.23 kg (24.76 lb)
A BladeCenter HX5 blade server combined with an IBM MAX5 expansion blade: - Height: 24.5 cm (9.7 in) (6U)
- Depth: 44.6 cm (17.6 in)
- Width: 5.8 cm (2.28 in)
- Maximum weight: 9.5 kg (21.0 lb)
| Environment: - Air temperature:
- Blade server on: 10°C to 35°C (50°F to 95°F). Altitude: 0 m to 914.4 m (0 ft to 3000 ft)
- Blade server on: 10°C to 32°C (50°F to 89.6°F). Altitude: 914.4 m to 2133.6 m (3000 ft to 7000 ft)
- Blade server off: 10°C to 43°C (50°F to 109.4°F). Altitude: 914.4 m to 2133.6 m (3000 ft to 7000 ft)
- Blade server shipping: -40°C to 60°C (-40°F to 140°F)
- Humidity:
- Blade server on: 8% to 80%
- Blade server off: 8% to 80%
- Blade server storage: 5% to 80%
- Blade server shipping: 5% to 100%
- Particulate contamination
Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.
|