Power worksheet
Use this worksheet to determine your power budget for the BladeCenter S system.
- Record the wattage for each of the devices that you will install in the BladeCenter S chassis.
Management policy
Number of power modules installed: ______
Note
If you install both disk storage modules, you must install 4 power modules.
Power source: ___ 110 V ac __ 220 V ac
Management policy to be used:
AC power source redundancy | |
AC power source redundancy with blade throttling allowed | |
Power module redundancy | |
Power module redundancy with blade throttling allowed | |
Non-redundant |
See Power management policies for a description of these policies.
Power consumption of BladeCenter S chassis components
Component | Maximum Watts | Installed |
---|---|---|
Midplane | 5W | Yes |
Media tray | 15W | Yes |
Fans (four) | 280W | Yes |
Advanced management module | 25W | Yes |
Power modules 1 and 2 | 24W | Yes |
Power modules 3 and 4 | 24W | |
I/O module (I/O module bay 1) | 45W | |
I/O module (I/O module bay 2) | 45W | |
SAS connectivity module | 65W | |
SAS connectivity module | 65W | |
SAS RAID controller module | 65W | |
Battery backup unit | 10W | |
SAS RAID controller module | 65W | |
Battery backup unit | 10W | |
Disk storage module | 120W | |
Disk storage module | 120W | |
Blade server bay 1 | ||
Blade server bay 2 | ||
Blade server bay 3 | ||
Blade server bay 4 | ||
Blade server bay 5 | ||
Blade server bay 6 | ||
Total wattage |
See Power allocation guidelines to ensure that the total wattage meets the power allocation guidelines for the power policy that you are using.
Use the IBM System x and BladeCenter Power Configurator to assist in planning for power.
Give documentation feedback