fuelg command errors
This topic lists error messages for the fuelg command.
See Common errors for a list of error messages that apply to all commands. See fuelg command for information about command syntax and examples of command use.
| Error message | Definition |
|---|---|
| -pme can not be 'none' when configuring -spl | The user attempts set the chassis power management and capping to none when a static power limit value is specified. |
| -pme must be other than 'none' when configuring -spl | The user attempts set the chassis power management and capping to none when a static power limit value is specified. |
| -pme must be provided when configuring -spl | The user attempts to specify a static power limit value without setting the chassis power management and capping value to static. |
| -ps and -dps cannot be enabled at the same time. | The user attempts to enable -ps and -dps at the same time. |
| -spl must be numeric if a percentage, or numeric with a 'W' appended if a wattage | The user attempts to enter a value that is in the wrong format for the -spl command option. |
| -spl must be provided when configuring -pme other than 'none' | The user attempts set the chassis power management and capping to static without specifying a static power limit value. |
| A power module failure in domain domain_number can result in an immediate shutdown. where domain_number identifies the power domain. | A power supply fails and the domain in which it is installed loses redundancy. The Flex System Enterprise Chassis might turn itself off, based on the power management configuration. |
| Blade must be powered on to enable/disable dps. | The user attempts to enable or disable dynamic power server mode for a compute node while its power is off. |
| Blade must be powered on to enable/disable fpop | The user attempts to enable or disable favoring performance over power for a compute node while its power is off. |
| Blade must be powered on to enable/disable pme | The user attempts to enable or disable power management and capping for a compute node while its power is off. |
| Blade must be powered on to enable/disable ps | The user attempts to enable or disable static low power saver mode for a compute node while its power is off. |
| Blade must be powered on to set pcap | The user attempts to set the power capping value for a compute node while its power is off. |
| Checking if power is preallocated to switch[number] failed. where the number I/O-bay number. | An error occurs while the CMM is checking if power is preallocated for the specified I/O module. |
| Effective CPU Speed not available. | An error occurs while the CMM is reading the effective CPU Speed. |
| Error reading blade power management capability. | An error occurs while the CMM is reading the compute node power management capability. |
| Error reading hot air recirculation data | An error occurs while the CMM is reading the hot air recirculation data. |
| Error reading runtime blade capability | An error occurs while the CMM is reading the runtime capability for a compute node. |
| Error reading soft minimum. | An error occurs while the CMM is reading the soft minimum value. |
| Error reading soft minimum, using guaranteed minimum instead. | An error occurs while the CMM is reading the soft minimum value. |
| Error writing data for the option -pme Please make sure the blade is powered on | The user attempts to enable power management and capping for a compute node that is turned off. |
| Getting blade health state parameters failed. | An error occurs while the CMM is reading the compute node health state parameters. |
| Getting blade pcap maximum value failed. | An error occurs while the CMM is reading the compute node power cap maximum value. |
| Getting blade pcap minimum value failed. | An error occurs while the CMM is reading the compute node power cap minimum value. |
| Getting blade power cap level failed. | An error occurs while the CMM is reading the compute nodepower cap level. |
| Getting Chassis Power Cap Range failed | An error occurs while the CMM is reading the chassis power cap level. |
| Getting domain latest power sample failed. | An error occurs while the CMM is reading the latest power domain sample. |
| Getting duty cycle numbers failed. | An error occurs while the CMM is reading the duty cycle numbers. |
| Getting duty cycle numbers of blade[node_number] failed. where node_number identifies the compute node. | An error occurs while the CMM is reading the duty cycle numbers of specified compute node. |
| Getting dynamic power management capability of blade[node_number] failed. where node_number identifies the compute node. | An error occurs while the CMM is reading the dynamic power management capability of specified compute node. |
| Getting information of power[number] failed. where the number identifies the specified power supply. | An error occurs while the CMM is reading data of specified power supply. |
| Getting name of mm[number] failed where the number identifies the specified CMM bay number. | An error occurs while the CMM is reading the CMM name. |
| Getting power allocation for blade[node_number] failed where node_number identifies the compute node. | An error occurs while the CMM is reading the power allocation information of the specified compute node. |
| Getting power cap level for blade[node_number] failed where node_number identifies the compute node. | An error occurs while the CMM is reading the power cap level of the specified compute node. |
| Getting power management policy for domain domain_number failed where domain_number is the number of the domain that was entered. | An error occurs while the CMM is reading the power management policy of the specified domain. |
| Getting power state of blade[node_number] failed. where node_number identifies the compute node. | An error occurs while the CMM is reading the power state of specified compute node. |
| Getting power values for blower[number] failed. where the number identifies the location of the component. | An error occurs while the CMM is reading the power values of specified chassis cooling unit. |
| Getting power values of Fanmux slot failed | An error occurs while the CMM is reading the power values of a fan logic module. |
| Getting power values for MM[number] failed. where the number identifies the location of the component. | An error occurs while the CMM is reading the power values of specified CMM. |
| Getting power values for switch[number] failed. where the number represents the specified I/O module. | An error occurs while the CMM is reading the power values of specified I/O module. |
| Getting power values of midplane within domain failed. | An error occurs while the CMM is reading the power values of midplane within domain. |
| Getting power values of mt[number] within domain failed. where the number represents the specified mt. | An error occurs while the CMM is reading the power values within domain of specified rear LED card. |
| Getting power values of PM Cooling Device number failed where the number represents the specified PM cooling device. | An error occurs while the CMM is reading the power values of specified power supply cooling device. |
| Getting status of domain domain_number failed where domain_number identifies the power domain. | An error occurs while the CMM is reading the status of specified domain. |
| Invalid option for this blade: option where option identifies the unacceptable option. | The user attempts to issue a command with an option which is invalid for the targeted compute node. |
| Maximum CPU Speed not available. | An error occurs while the CMM is reading maximum CPU Speed. |
| pcap must be between min and max Watts. where min and max represent the minimum and maximum wattage values permitted. | The user input for power cap is out of the range. |
| Power value is not in the guaranteed capping range. | The user attempts to set a power value that is out of range. |
| The -spl wattage value must be in the range of lower_limit and upper_limit where lower_limit and upper_limit indicate the upper and lower wattage range limits. | The user attempts to set a static power limit wattage value that is out of range. |
| The -spl percentage value must convert to a wattage value in the range of lower_limit and upper_limit where lower_limit and upper_limit indicate the upper and lower wattage range limits. | The user attempts to set a static power limit percentage value that is outside of the wattage range. |
| The acoustic attenuation setting could not be set because compute nodes in the chassis require more cooling than the selected policy would provide. | The user attempts to set an acoustic attenuation setting that conflicts with chassis cooling requirements. |
| The Power Management Policy is not applicable when a 1200W or 1400W power module is installed. | The user attempts to select a power management policy that is not compatible with power modules installed in the chassis. |
| There is no air flow trending data to display. | An error occurs while the CMM is reading air flow trending data. |
| There is no thermal trending data to display. | An error occurs while the CMM is reading thermal trending data. |
| There is no trending data to display. | An error occurs while the CMM is reading power trending data. |
| This blade does not support power capping | A user tries to enable power capping for a compute node that does not support this feature. |
| Unable to change power management settings, domain may be oversubscribed. | An error occurs while the CMM is configuring the power management policy. |