  • Diagnostic Code:

    04010401

    04010402

    04010403

    04010404

    04010405

    Full Sensor Name (Sensor Name In SDR):

    Fan%_Speed (% = Fan number)

    Sensor Type:

    Fan

    Event Severity:

    Critical

    Description:

    Lower Non-Recoverable - Going Low - Asserted

    Message:

    Fan% speed is too low.

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010410

    Full Sensor Name (Sensor Name In SDR):

    SYS_12V

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Lower Non-Recoverable - Going Low - Asserted

    Message:

    12V voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010210

    Full Sensor Name (Sensor Name In SDR):

    SYS_12V

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Lower Critical - Going Low - Asserted

    Message:

    12 voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010010

    Full Sensor Name (Sensor Name In SDR):

    SYS_12V

    Sensor Type:

    Voltage

    Event Severity:

    Warning

    Description:

    Lower Non-Critical - Going Low - Asserted

    Message:

    12V voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010B10

    Full Sensor Name (Sensor Name In SDR):

    SYS_12V

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    12V voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010910

    Full Sensor Name (Sensor Name In SDR):

    SYS_12V

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    12V voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010710

    Full Sensor Name (Sensor Name In SDR):

    SYS_12V

    Sensor Type:

    Voltage

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    12V voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010411

    Full Sensor Name (Sensor Name In SDR):

    SYS_5V

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Lower Non-Recoverable - Going Low - Asserted

    Message:

    5V voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010211

    Full Sensor Name (Sensor Name In SDR):

    SYS_5V

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Lower Critical - Going Low - Asserted

    Message:

    5V voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010011

    Full Sensor Name (Sensor Name In SDR):

    SYS_5V

    Sensor Type:

    Voltage

    Event Severity:

    Warning

    Description:

    Lower Non-Critical - Going Low - Asserted

    Message:

    5V voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010B11

    Full Sensor Name (Sensor Name In SDR):

    SYS_5V

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    5V voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010911

    Full Sensor Name (Sensor Name In SDR):

    SYS_5V

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    5V voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010711

    Full Sensor Name (Sensor Name In SDR):

    SYS_5V

    Sensor Type:

    Voltage

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    5V voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010412

    Full Sensor Name (Sensor Name In SDR):

    SYS_3.3.V

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Lower Non-Recoverable - Going Low - Asserted

    Message:

    3.3V voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010212

    Full Sensor Name (Sensor Name In SDR):

    SYS_3.3.V

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Lower Critical - Going Low - Asserted

    Message:

    3.3V voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010012

    Full Sensor Name (Sensor Name In SDR):

    SYS_3.3.V

    Sensor Type:

    Voltage

    Event Severity:

    Warning

    Description:

    Lower Non-Critical - Going Low - Asserted

    Message:

    3.3V voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010B12

    Full Sensor Name (Sensor Name In SDR):

    SYS_3.3.V

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    3.3V voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010912

    Full Sensor Name (Sensor Name In SDR):

    SYS_3.3.V

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    3.3V voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010712

    Full Sensor Name (Sensor Name In SDR):

    SYS_3.3.V

    Sensor Type:

    Voltage

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    3.3V voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010413

    02010414

    Full Sensor Name (Sensor Name In SDR):

    CPU%_VCORE (% = CPU number)

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Lower Non-Recoverable - Going Low - Asserted

    Message:

    CPU% VCORE voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010213

    02010214

    Full Sensor Name (Sensor Name In SDR):

    CPU%_VCORE (% = CPU number)

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Lower Critical - Going Low - Asserted

    Message:

    CPU% VCORE voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010013

    02010014

    Full Sensor Name (Sensor Name In SDR):

    CPU%_VCORE (% = CPU number)

    Sensor Type:

    Voltage

    Event Severity:

    Warning

    Description:

    Lower Non-Critical - Going Low - Asserted

    Message:

    CPU% VCORE voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010B13

    02010B14

    Full Sensor Name (Sensor Name In SDR):

    CPU%_VCORE (% = CPU number)

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    CPU% VCORE voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010913

    02010914

    Full Sensor Name (Sensor Name In SDR):

    CPU%_VCORE (% = CPU number)

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    CPU% VCORE voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    02010713

    02010714

    Full Sensor Name (Sensor Name In SDR):

    CPU%_VCORE (% = CPU number)

    Sensor Type:

    Voltage

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    CPU% VCORE voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010B20

    Full Sensor Name (Sensor Name In SDR):

    Inlet_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    Inlet temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010920

    Full Sensor Name (Sensor Name In SDR):

    Inlet_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    Inlet temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010720

    Full Sensor Name (Sensor Name In SDR):

    Inlet_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    Inlet temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010B21

    Full Sensor Name (Sensor Name In SDR):

    Outlet_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    Outlet temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010921

    Full Sensor Name (Sensor Name In SDR):

    Outlet_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    Outlet temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010721

    Full Sensor Name (Sensor Name In SDR):

    Outlet_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    Outlet temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010722

    01010723

    Full Sensor Name (Sensor Name In SDR):

    CPU0%_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    CPU% temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010B26

    01010B27

    Full Sensor Name (Sensor Name In SDR):

    CPU%_VR_Temp (% = CPU Number)

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    CPU% VR temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010926

    01010927

    Full Sensor Name (Sensor Name In SDR):

    CPU%_VR_Temp (% = CPU Number)

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    CPU% VR temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010726

    01010727

    Full Sensor Name (Sensor Name In SDR):

    CPU%_VR_Temp (% = CPU Number)

    Sensor Type:

    Temperature

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    CPU% VR temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010B28

    Full Sensor Name (Sensor Name In SDR):

    Node_PBP_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    Power IC is over temperature

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010928

    Full Sensor Name (Sensor Name In SDR):

    Node_PBP_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    Power IC is over temperature

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010728

    Full Sensor Name (Sensor Name In SDR):

    Node_PBP_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    Power IC is over temperature

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010B29

    Full Sensor Name (Sensor Name In SDR):

    PCH_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    PCH temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010929

    Full Sensor Name (Sensor Name In SDR):

    PCH_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    PCH temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010729

    Full Sensor Name (Sensor Name In SDR):

    PCH_Temp

    Sensor Type:

    Temperature

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    PCH temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010B2A

    01010B2B

    Full Sensor Name (Sensor Name In SDR):

    DIMMG%_Temp (% = Group number)

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    DIMM Group% temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0101092A

    0101092B

    Full Sensor Name (Sensor Name In SDR):

    DIMMG%_Temp (% = Group number)

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    DIMM Group% temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0101072A

    0101072B

    Full Sensor Name (Sensor Name In SDR):

    DIMMG%_Temp (% = Group number)

    Sensor Type:

    Temperature

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    DIMM Group% temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010B2C

    01010B2D

    01010B2E

    01010B2F

    Full Sensor Name (Sensor Name In SDR):

    DIMM%_VR_Temp (% = Channel number)

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    DIMM Group% VR temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0101092C

    0101092D

    0101092E

    0101092F

    Full Sensor Name (Sensor Name In SDR):

    DIMM%_VR_Temp (% = Channel number)

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    DIMM Group% VR temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0101072C

    0101072D

    0101072E

    0101072F

    Full Sensor Name (Sensor Name In SDR):

    DIMM%_VR_Temp (% = Channel number)

    Sensor Type:

    Temperature

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    DIMM Group% VR temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010B91

    Full Sensor Name (Sensor Name In SDR):

    Node_IIN

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    Node input current is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010991

    Full Sensor Name (Sensor Name In SDR):

    Node_IIN

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    Node input current is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010791

    Full Sensor Name (Sensor Name In SDR):

    Node_IIN

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    Node input current is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010B92

    Full Sensor Name (Sensor Name In SDR):

    Node_IOUT

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    Node output current is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010992

    Full Sensor Name (Sensor Name In SDR):

    Node_IOUT

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    Node output current is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010792

    Full Sensor Name (Sensor Name In SDR):

    Node_IOUT

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    Node output current is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010093

    Full Sensor Name (Sensor Name In SDR):

    Node_VIN

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Warning

    Description:

    Lower Non-Critical - Going Low - Asserted

    Message:

    Node intput voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010B93

    Full Sensor Name (Sensor Name In SDR):

    Node_VIN

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    Node intput voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010993

    Full Sensor Name (Sensor Name In SDR):

    Node_VIN

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    Node intput voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010793

    Full Sensor Name (Sensor Name In SDR):

    Node_VIN

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    Node intput voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010094

    Full Sensor Name (Sensor Name In SDR):

    Node_VOUT

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Warning

    Description:

    Lower Non-Critical - Going Low - Asserted

    Message:

    Node output voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010B94

    Full Sensor Name (Sensor Name In SDR):

    Node_VOUT

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    Node output voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010994

    Full Sensor Name (Sensor Name In SDR):

    Node_VOUT

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    Node output voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010794

    Full Sensor Name (Sensor Name In SDR):

    Node_VOUT

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    Node output voltage is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010B95

    Full Sensor Name (Sensor Name In SDR):

    Node_PIN

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    Node input power is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010995

    Full Sensor Name (Sensor Name In SDR):

    Node_PIN

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    Node input power is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010795

    Full Sensor Name (Sensor Name In SDR):

    Node_PIN

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    Node input power is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010B96

    Full Sensor Name (Sensor Name In SDR):

    Node_POUT

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    Node output power is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010996

    Full Sensor Name (Sensor Name In SDR):

    Node_POUT

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    Node output power is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010796

    Full Sensor Name (Sensor Name In SDR):

    Node_POUT

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Warning

    Description:

    Upper Non-Critical - Going High - Asserted

    Message:

    Node output power is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010B9A

    Full Sensor Name (Sensor Name In SDR):

    CPU_Power

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    CPU power consumption is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B01099A

    Full Sensor Name (Sensor Name In SDR):

    CPU_Power

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    CPU power consumption is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0201049C

    Full Sensor Name (Sensor Name In SDR):

    BAT_Volt

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Lower Non-Recoverable - Going Low - Asserted

    Message:

    Battery voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0201029C

    Full Sensor Name (Sensor Name In SDR):

    BAT_Volt

    Sensor Type:

    Voltage

    Event Severity:

    Critical

    Description:

    Lower Critical - Going Low - Asserted

    Message:

    Battery voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0201009C

    Full Sensor Name (Sensor Name In SDR):

    BAT_Volt

    Sensor Type:

    Voltage

    Event Severity:

    Warning

    Description:

    Lower Non-Critical - Going Low - Asserted

    Message:

    Battery voltage is too low

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    086F06A0

    Full Sensor Name (Sensor Name In SDR):

    PSU_Mismatch

    Sensor Type:

    Power Supply

    Event Severity:

    Critical

    Description:

    Configuration Error - Asserted

    Message:

    There are different capacity or voltage of PSUs that are plugged in chassis.

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Restart the server.

    3. Suggest to use the same type of PSUs. 4. Contact your Lenovo service representative for support

  • Diagnostic Code:

    086F00A1

    086F00A2

    Full Sensor Name (Sensor Name In SDR):

    PSU%_Status (% = PSU number)

    Sensor Type:

    Power Supply

    Event Severity:

    Critical

    Description:

    Presence detected - Deasserted

    Message:

    PSU is unplugged

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check PSU is unpluged or not. If yes, please plug PSU back.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    086F01A1

    086F01A2

    Full Sensor Name (Sensor Name In SDR):

    PSU%_Status (% = PSU number)

    Sensor Type:

    Power Supply

    Event Severity:

    Critical

    Description:

    Power Supply Failure detected - Asserted

    Message:

    PSU is OCP or OVP

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    086F03A1

    086F03A2

    Full Sensor Name (Sensor Name In SDR):

    PSU%_Status (% = PSU number)

    Sensor Type:

    Power Supply

    Event Severity:

    Critical

    Description:

    Power Supply input lost (AC/DC) - Asserted

    Message:

    AC lost

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010BA3

    0B010BA4

    Full Sensor Name (Sensor Name In SDR):

    PSU%_POUT (% = PSU number)

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    PSU output power is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B0109A3

    0B0109A4

    Full Sensor Name (Sensor Name In SDR):

    PSU%_POUT (% = PSU number)

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    PSU output power is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    01010BA5

    01010BA6

    Full Sensor Name (Sensor Name In SDR):

    PSU%_Temp (% = PSU number)

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    PSU ambient temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    010109A5

    010109A6

    Full Sensor Name (Sensor Name In SDR):

    PSU%_Temp (% = PSU number)

    Sensor Type:

    Temperature

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    PSU ambient temperature is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    040104A7

    040104A8

    Full Sensor Name (Sensor Name In SDR):

    PSU%_FAN_Speed (% = PSU number)

    Sensor Type:

    Fan

    Event Severity:

    Critical

    Description:

    Lower Non-Recoverable - Going Low - Asserted

    Message:

    PSU FAN speed is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    04010BA7

    04010BA8

    Full Sensor Name (Sensor Name In SDR):

    PSU%_FAN_Speed (% = PSU number)

    Sensor Type:

    Fan

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    PSU FAN speed is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010BAA

    Full Sensor Name (Sensor Name In SDR):

    FAN_BP_Power

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    FAN backplane power consumption is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B010BAB

    Full Sensor Name (Sensor Name In SDR):

    HDD_BP_Power

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Non-Recoverable - Going High - Asserted

    Message:

    HDD backplane power consumption is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0B0109AB

    Full Sensor Name (Sensor Name In SDR):

    HDD_BP_Power

    Sensor Type:

    Other Units-based sensor

    Event Severity:

    Critical

    Description:

    Upper Critical - Going High - Asserted

    Message:

    HDD backplane power consumption is too high

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    160901C0

    Full Sensor Name (Sensor Name In SDR):

    BMC_Boot_Up

    Sensor Type:

    Microcontroller / Coprocessor

    Event Severity:

    Info

    Description:

    Device Enabled - Asserted

    Message:

    BMC boot up successfully.

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    226F00C1

    Full Sensor Name (Sensor Name In SDR):

    ACPI_PWR_Status

    Sensor Type:

    System ACPI Power

    Event Severity:

    Info

    Description:

    S0/G0 'working - Asserted

    Message:

    The system is under S0 state.

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    226F05C1

    Full Sensor Name (Sensor Name In SDR):

    ACPI_PWR_Status

    Sensor Type:

    System ACPI Power

    Event Severity:

    Info

    Description:

    S5/G2 - soft-off - Asserted

    Message:

    The system is under S5 state.

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    146F00C2

    Full Sensor Name (Sensor Name In SDR):

    Button_Status

    Sensor Type:

    Button / Switch

    Event Severity:

    Info

    Description:

    Power Button pressed - Asserted

    Message:

    Someone pressed the power button

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    106F02C3

    Full Sensor Name (Sensor Name In SDR):

    SEL_Status

    Sensor Type:

    Event Logging Disabled

    Event Severity:

    Info

    Description:

    Log Area Reset/Cleared - Asserted

    Message:

    The log area of SEL is cleared.

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    106F05C3

    Full Sensor Name (Sensor Name In SDR):

    SEL_Status

    Sensor Type:

    Event Logging Disabled

    Event Severity:

    Info

    Description:

    SEL Almost Full - Asserted

    Message:

    The SEL is almost full.

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    236F00C4

    Full Sensor Name (Sensor Name In SDR):

    IPMI_Watchdog

    Sensor Type:

    Watchdog 2

    Event Severity:

    Critical

    Description:

    Time expired - status only (no action and no interrupt) - Asserted

    Message:

    The watchdog timer is expired.

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    236F01C4

    Full Sensor Name (Sensor Name In SDR):

    IPMI_Watchdog

    Sensor Type:

    Watchdog 2

    Event Severity:

    Critical

    Description:

    Hard Reset - Asserted

    Message:

    The Hard Reset is triggered by watchdog.

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    236F02C4

    Full Sensor Name (Sensor Name In SDR):

    IPMI_Watchdog

    Sensor Type:

    Watchdog 2

    Event Severity:

    Critical

    Description:

    Power Down - Asserted

    Message:

    The Power Down is triggerred by watchdog.

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    236F03C4

    Full Sensor Name (Sensor Name In SDR):

    IPMI_Watchdog

    Sensor Type:

    Watchdog 2

    Event Severity:

    Critical

    Description:

    Power Cycle - Asserted

    Message:

    The Power Cycle is triggered by watchdog.

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    076F01C5

    076F01C6

    Full Sensor Name (Sensor Name In SDR):

    CPU%_Status (% = CPU number)

    Sensor Type:

    Processor

    Event Severity:

    Critical

    Description:

    Thermal Trip - Asserted

    Message:

    CPU temperature is too high. At the same time, system will be shutdown.

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    070301C7

    Full Sensor Name (Sensor Name In SDR):

    PROC_Hot

    Sensor Type:

    Processor

    Event Severity:

    Warning

    Description:

    State Asserted - Asserted

    Message:

    CPU begins to throttle because its temperature is too high.

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    076F0AC7

    Full Sensor Name (Sensor Name In SDR):

    PROC_Hot

    Sensor Type:

    Processor

    Event Severity:

    Warning

    Description:

    Processor Automatically Throttled - Asserted

    Message:

    CPU begins to throttle which is triggered by PSU alert.

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Contact your Lenovo service representative for support

  • Diagnostic Code:

    CF6F00C9

    Full Sensor Name (Sensor Name In SDR):

    Chassis_Control

    Sensor Type:

    Customer Sensor Type

    Event Severity:

    Info

    Description:

    Chassis Control - Asserted

    Message:

    BMC gets Chassis Control command.

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    070301D0

    Full Sensor Name (Sensor Name In SDR):

    CPU_CATERR

    Sensor Type:

    Processor

    Event Severity:

    Critical

    Description:

    State Asserted - Asserted

    Message:

    Catastrophic error happened.

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Restart the server.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    070301D1

    Full Sensor Name (Sensor Name In SDR):

    CPU_VR_Fault

    Sensor Type:

    Processor

    Event Severity:

    Critical

    Description:

    State Asserted - Asserted

    Message:

    CPU VR fault.

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Restart the server.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0C0301D2

    Full Sensor Name (Sensor Name In SDR):

    Mem_Therm_Trip

    Sensor Type:

    Memory

    Event Severity:

    Critical

    Description:

    State Asserted - Asserted

    Message:

    Memory temperature is too high. At the same time, system will be shutdown.

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    196F01D3

    Full Sensor Name (Sensor Name In SDR):

    PCH_Therm_Trip

    Sensor Type:

    Chipset

    Event Severity:

    Critical

    Description:

    Thermal Trip - Asserted

    Message:

    PCH temperature is too high. At the same time, system will be shutdown.

    Actions:

    1. Check the Lenovo support website for an applicable retain tip or firmware update that applies to this error.

    2. Check Fan status. if Fan is broken, please replace the new Fan.

    3. Contact your Lenovo service representative for support

  • Diagnostic Code:

    0D6F01D4

    Full Sensor Name (Sensor Name In SDR):

    HDD_Status

    Sensor Type:

    Drive Slot (Bay)

    Event Severity:

    Critical

    Description:

    Drive Fault - Asserted

    Message:

    HDD fault.

    Actions:

    1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this error.

    2. Replace HDD.

    3. Contact your Lenovo service representative for support.

  • Diagnostic Code:

    1D6F02E0

    Full Sensor Name (Sensor Name In SDR):

    BIOS_Boot_up

    Sensor Type:

    System Boot / Restart Initiated

    Event Severity:

    Info

    Description:

    Initiated by warm reset - Asserted

    Message:

    BIOS boot up and it's initiated by warm reset.

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    0C6F00E2

    Full Sensor Name (Sensor Name In SDR):

    Memory_Status

    Sensor Type:

    Memory

    Event Severity:

    Critical

    Description:

    Correctable ECC or other correctable memory error - Asserted

    Message:

    A single bit error is occurred In memory. This error will be repaired automatically.

    Actions:

    1. If the node has recently been installed, moved, serviced, or upgraded, verify that the DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel. If either of these conditions is found, correct and retry with the same DIMM

    2. If problem re-occurs on the same DIMM connector, swap the other DIMMs on the same memory channel across channels one at a time to a different memory channel or Processor. (check service information for this product/Install guide for population requirements for sparing/paring modes). If problem follows a moved DIMM to a different memory channel, replace that DIMM.

  • Diagnostic Code:

    0C6F01E2

    Full Sensor Name (Sensor Name In SDR):

    Memory_Status

    Sensor Type:

    Memory

    Event Severity:

    Critical

    Description:

    Uncorrectable ECC or other uncorrectable memory error - Asserted

    Message:

    A multiple bits error is occurred in memory. This error will cause system to be hang up.

    Actions:

    1. Check the Lenovo support website for an applicable service bulletin or firmware update that applies to this memory error.

    2. If the node has recently been installed, moved, serviced, or upgraded, verify that the DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel. If either of these conditions is found, correct and retry with the same DIMM.

    3. If no problem is observed on the DIMM connectors and the problem persists, replace the DIMM identified by LightPath and/or event log entry. 4. If problem re-occurs on the same DIMM connector, swap the other DIMMs on the same memory channel across channels one at a time to a different memory channel or Processor. (check service information for this product/Install guide for population requirements for sparing/paring modes). If problem follows a moved DIMM to a different memory channel, replace that DIMM. 5. (Trained service technician only) Remove affected Processor and inspect Processor socket pins for damaged or mis-aligned pins. If damage is found, or this is an upgrade Processor, replace the system board. If there are multiple Processor’s, swap Processor’s to move affected Procesor to another Processor socket and retry. If problem follows the affected Processor (or there is only one Processor), replace the affected Processor. 6. (Trained technician only)If problem stays with the original DIMM connector, re-inspect DIMM connector for foreign material and remove, if found. If connector is damaged, replace system board

  • Diagnostic Code:

    0C6F04E2

    Full Sensor Name (Sensor Name In SDR):

    Memory_Status

    Sensor Type:

    Memory

    Event Severity:

    Critical

    Description:

    Memory Device Disabled - Asserted

    Message:

    Memory fault occurs and it's disabled by BIOS.

    Actions:

    1. If the DIMM was disabled because of a memory fault, follow the procedure for that event.

    2. If problem persists, Power cycle the node from management console.

    3. Reset UEFI to default settings. 4. Swap/reseat the DIMM from the disabled slot with a matching DIMM. If the slot remains disabled, (trained technician only) replace system board

  • Diagnostic Code:

    296F00E3

    Full Sensor Name (Sensor Name In SDR):

    Battery_Status

    Sensor Type:

    Battery

    Event Severity:

    Warning

    Description:

    battery low (predictive failure) - Asserted

    Message:

    The battery is too low.

    Actions:

    1. If the system was recently installed, moved, or serviced, make sure the battery is properly seated.

    2. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this error.

    3. Replace CMOS battery. 4. (Trained technician only) Replace the system board.

  • Diagnostic Code:

    126F05E4

    Full Sensor Name (Sensor Name In SDR):

    Timestamp

    Sensor Type:

    System Event

    Event Severity:

    Info

    Description:

    Timestamp Clock Synch - Asserted

    Message:

    The system time in BMC was synchronized with BIOS.

    Actions:

    It is just an information. Users don't need to do anything.

  • Diagnostic Code:

    1E6F03E5

    Full Sensor Name (Sensor Name In SDR):

    Device_OPROM

    Sensor Type:

    Boot Error

    Event Severity:

    Warning

    Description:

    Invalid boot sector - Asserted

    Message:

    Optoin ROMs are full in memory space.

    Actions:

    Check the Lenovo support website for any applicable service bulletin or UEFI or adapter firmware update that applies to this error. Note: It may be necessary to disable unused option ROMs from BIOS setup.

  • Diagnostic Code:

    136F07E6

    Full Sensor Name (Sensor Name In SDR):

    PCIE_Status

    Sensor Type:

    Critical Interrupt

    Event Severity:

    Critical

    Description:

    Bus Correctable Error - Asserted

    Message:

    A single bit error is occurred in PCIe bus. This error will be repaired automatically.

    Actions:

    If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a. Reset adapter and any attached cables. b. Reload Device Driver. c. If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or te ASU Utility.

  • Diagnostic Code:

    136F08E6

    Full Sensor Name (Sensor Name In SDR):

    PCIE_Status

    Sensor Type:

    Critical Interrupt

    Event Severity:

    Critical

    Description:

    Bus Uncorrectable Error - Asserted

    Message:

    A multiple bits error is occurred in PCIe bus. This error will cause system to be hang up.

    Actions:

    1. Check the Lenovo support website for an applicable device driver, firmware update, version of service information for this product or other information that applies to this error. Load new device driver and any required firmware updates.

    2. if this node and/or any attached cables were recently installed, moved, serviced or upgraded, a. Reset adapter and any attached cables. b. Reload Device Driver. c. If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or te ASU Utility.

    3. If problem persists, then remove Adapter Card. If system reboots successfully without the adapter, replace that card.