Diagnostic error messages

Use this information to resolve any issues that were found.

MessageDescriptionAction
Memory Test FailedMemory Failure was detected.1.Please check ECC and error logs in setup, test reports and verify ECC indicators on system board to identify failing module. ECC circuitry may have recovered the failing module and further data is included in the report under critical error logs for verification test. 2.Reseat firstly. If it still fails, then, replace defective module and contact Lenovo Customer Service for further support options.
MegaRaid Test FailedRaid controller test has detected an error.1.Please refer to drive status in the test results to see if RAID drives are responding. If no response, check installed drivers to see if active. If drive degraded, one of the raid drives has failed and needs to be replaced. 2.Make sure all drive carriers are in place and locked position. Make sure RAID BIOS settings are properly set. 3. Replace a raid card. 4. If still fails, please contact Lenovo Customer Service for further options.
LSI Test FailedRaid controller test has detected an error.1.Please refer to drive status in the test results to see if RAID drives are responding. If no response, check installed drivers to see if active. If drive degraded, one of the raid drives has failed and needs to be replaced. 2.Make sure all drive carriers are in place and locked position. Make sure RAID BIOS settings are properly set. 3.Replace a raid card. 4. If still fails, please contact Lenovo Customer Service for further options.