run command
Use the run command to run the diagnostics program of the remote server.
To enable or disable advanced memory test, refer to Performing memory test.
Restart the remote server before running the diagnostics program. If the message
System reboot is required, confirm to continue (yes/no)
is displayed, input yes/y to run the diagnostics program, or input no/n to exit.For the ThinkServer/WenTian/KaiTian servers, only WR5220 G3 and WR5228 G3 support the diags function, and it only supports the hdd, hdd_full, mem, and mem_full parameters.
run command syntax
OneCli.exe [misc] diags run [options] [connection options]
Parameter | Required/Optional | Notes |
---|---|---|
--bmc, -b | Required | Refer to Table 2. |
| Optional | Refer to Table 2. |
--item | Optional | The values include: hdd, hdd_full, mem, mem_full, and pmem. If not specified, hdd, mem, and pmem are the default parameters. The value is case insensitive. Note pmemstands for Intel Optane DC Persistent Memory Module. |
--force | Optional | If specified, it will run the diagnostics program without interaction. |
Example of the run command
OneCli.exe diags run --bmc userid:password@IP --item mem_full,hdd,pmem