Miscellaneous
The topics in this section describe how to use the Lenovo XClarity Essentials OneCLI miscellaneous commands.
The following table list the miscellaneous commands supported by XClarity Essentials OneCLI.
Commands | Description |
---|---|
bmcpassword | Remotely change password of BMC accounts when first login or password expired. For more information, refer to bmcpassword command. |
cmos | Execute the CMOS action. For more information, refer to cmos command. |
deployos | Deploy Windows/Linux/Vmware to the ThinkSystem V2 servers base on LXPM of the server. For more information, refer to deployos command. |
edgeserver | Manage the status of the ThinkEdge servers. For more information, refer to edgeserver command. |
encrypt | Encrypt credentials in plain text file. For more information, refer to encrypt command. |
ffdc | Collect the FFDC of BMC/ESXi/CMM/SMM. For more information, refer to ffdc command. |
fpusb | Set and view the configurations of the front panel USB port. For more information, refer to fpusb commands. |
hddlocate | Manage the LED status of hard disk drive. For more information, refer to hddlocate command. |
hostinterface | Manage Host Interface of BMC Redfish. For more information, refer to hostinterface command. |
logmgr | Manage BMC event logs. For more information, refer to logmgr commands. |
multibmcpassword | Remotely change password of BMC accounts for multiple systems when first login or password expired. For more information, refer to multibmcpassword command. |
multicmos | Execute CMOS action for the multiple servers. For more information, refer to multicmos command. |
multideployos | Deploy Windows/Linux/Vmware to multiple ThinkSystem V2 servers. For more information, refer to multideployos command. |
multiffdc | Obtain the BMC/SMM FFDC logs from multiple servers. For more information, refer to multiffdc command. |
multiportctrl | query, enable, and disable CIM/IPMILAN/IPMIKCS connection for the multiple servers. For more information, refer to multiportctrl command. |
multiraid | Remotely create, clear, and save the RAID configuration for multiple systems. For more information, refer to multiraid command. |
multirebootbmc | Manually reboot BMC for the multiple servers. For more information, refer to multirebootbmc command. |
multiospower | Turn on, turn off and restart the server, obtain the server power state, and restart the server to BIOS setup. For more information, refer to multiospower commands. |
multiserase | Erase all data on disks for multiple severs at the same time. For more information, refer to multiserase command. |
multiservicedata | Obtain service data information from multiple BMC. For more information, refer to multiservicedata command. |
multiservicelog | Obtain BMC Service Data Log of the multiple servers. For more information, refer to multiservicelog command. |
multisyshealth | Remotely collect system health information for multiple systems. For more information, refer to multisyshealth command. |
multiuefipassword | Set or change the power-on and administrator passwords for the multiple servers. For more information, refer to multiuefipassword command. |
multivm | List, mount, or unmout the virtual medias on multiple BMC. For more information, refer to multivm commands. |
ospower | Power on, power off, or restart host OS. For more information, refer to ospower command. |
portctrl | Query/enable/disable the cim/ipmilan/ipmikcs connection. For more information, refer to portcrl command. |
raid | Create, clear, and save the RAID configurations. For more information, refer to raid command. |
rebootbmc | Restart BMC. For more information, refer to rebootbmc command. |
rebootcmm | Restart CMM. For more information, refer to rebootcmm command. |
rebootiom | Restart I/O Module on the Flex chassis. For more information, refer to rebootiom command. |
rebootsmm | Restart SMM. For more information, refer to rebootsmm command. |
reseatblade | Reseat the blades on the Flex chassis. For more information, refer to reseatblade command. |
reseatcmm | Reseat CMM. For more information, refer to reseatcmm command. |
reseatswitch | Reseat the switch on the Flex chassis. For more information, refer to reseatswitch command. |
restorebmu | Restore the BMU status on BMC. For more information, refer to restorebmu command. |
restoresmm | Restore the SMM update progress. For more information, refer to restoresmm command. |
rpp | Assert and deassert Remote Physical Presence(RPP), or obtain its status. For more information, refer to rpp commands. |
serase | Securely and permanently erase the data of hard disk drives in the BMU mode. For more information, refer to serase command. |
servicedata | Obtain service data information from BMC. For more information, refer to servicedata command. |
servicelog | Obtain service data log from BMC. For more information, refer to servicelog command. |
smartdata | Get the disk drive SMART data. For more information, refer to smartdata command. |
smmlan | Disable or enable SMM LAN. For more information, refer to smmlan commands. |
switchcmm | Toggle active CMM. For more information, refer to switchcmm command. |
sysguard | Manage BMC system guard. For more information, refer to sysguard command. |
syshealth | Query system health status. For more information, refer to syshealth command. |
usblan | Enable or disable USB LAN. For more information, refer to usblan command. |
uefipassword | Set or change the power-on and administrator passwords. For more information, refer to uefipassword command. |
vm | List, mount, or unmount the virtual media. For more information, refer to vm commands. |