Skip to main content

New setting names on ThinkSystem V4 platform

This section provides the UEFI and BMC setting name examples between the ThinkSystem V1/V2/V3 and V4 platforms.

Note
The ThinkSystem V4 platform aligns its settings in compliance to recent Redfish standard, so the format of UEFI and BMC settings has been changed. To read and configure BMC and UEFI settings, users must use the latest versions of OneCLI 5.x, BoMC 14.x, and UpdateXpress 5.x.

Matrix of UEFI setting names

Table 1. Matrix of UEFI setting names (example)
ThinkSystem V1/V2/V3 platformsThinkSystem V4 platform

Processors.TurboMode

UEFI.Processors_TurboMode

BootOrder.BootOrder

UEFI.BootOrder_BootOrder_<N>

BootOrder.CDDVDROMBootOrder

UEFI.BootOrder_DVDROMPriority_1

DevicesandIOPorts.Device_OnboardVideo

UEFI.DevicesandIOPorts_EnDisDevice_OnboardVideo

DevicesandIOPorts.Device_Slot<N>

UEFI.DevicesandIOPorts_EnDisDevice_Slot<N>

DevicesandIOPorts.PCIeGen_Slot<N>

UEFI.DevicesandIOPorts_PCIeGen_Slot<N>

DevicesandIOPorts.Slot<N>Bifurcation

UEFI.DevicesandIOPorts_Bifurcation_Slot<N>

iSCSI.AttemptName.<N>

UEFI.iSCSI_AttemptName_<N>

SystemRecovery.F1StartControl

UEFI.SystemSettings_F1StartControl

Processors.CPUPstateControl

UEFI.Processors_CPUP_stateControl

Processors.CStates

UEFI.Processors_C_States

Processors.HyperThreading

UEFI.Processors_Hyper_Threading

Processors.L2RFOPrefetcher

UEFI.Processors_L2_RFO_Prefetcher

Processors.P-StateHysteresis

UEFI.Processors_P_State_Hysteresis

Processors.PCHPCIeRelaxedOrdering

UEFI.Processors_PCH_PCIe_Relaxed_Ordering

Memory.MirrorFail-over

UEFI.Memory_MirrorFail_over

TrustedComputingGroup.SHA-1PCRBank

UEFI.TrustedComputingGroup_SHA_1PCRBank

TrustedComputingGroup.DeviceOperation

UEFI.TrustedComputingGroup_DeviceOperation

BootModes.SystemBootMode

UEFI.BootModes_SystemBootMode

SecureBootConfiguration.SecureBootSetting

UEFI.SecureBootConfiguration_SecureBootSetting

Matrix of BMC setting names

Table 2. Matrix of BMC setting names (example)
ThinkSystem V1/V2/V3 platformsThinkSystem V4 platform

IMM.SSLPort

BMC.HTTPSPort

IMM.RemotePresencePortControl

BMC.RemotePresenceEnabled

IMM.SSDPPortControl

BMC.SSDPEnabled

IMM.SMTP_ServerName

BMC.SMTPServerHostname

IMM.SMTP_Password

BMC.SMTPUserPassword

IMM.SMTP_UserName

BMC.SMTPUserName

IMM.IMMInfo_Name

BMC.ServerConfigSystemName

IMM.WebTimeout

BMC.WebUISessionTimeoutMinutes

IMM.Password.2

BMC.Password.2

IMM.LoginRole.2

BMC.AuthorityLevel.2

IMM.AuthorityRoleName.2

BMC.RoleName.2

IMM.GRP_GroupDomain.1

BMC.LDAPGroupDomain.1

IMM.GRP_GroupName.1

BMC.LDAPGroupGroupName.1

IMM.GRP_GroupRole.1

BMC.LDAPGroupRole.1

IMM.SNMP_AgentPort

BMC.SNMPv3AgentPort

IMM.SNMP_TrapPort

BMC.SNMPTrapPort

IMM.SNMPAlerts_CriticalAlertCategory

BMC.SNMPAlertCritical

IMM.RemoteAlertRecipient_Name.1

BMC.RemoteAlertRecipientName.1

IMM.RemoteAlertRecipient_CriticalAlertsCategory.1

BMC.RemoteAlertRecipientCriticalAlertsCategory.1

IMM.RemoteAlertRecipient_Method.1

BMC.RemoteAlertRecipientMethod.1

IMM.RemoteAlertRecipient_Email.1

BMC.RemoteAlertRecipientEmail.1