跳至主要内容

Routine inspection for a remote server

The UpdateXpress application supports the routine inspection for a remote server.

Prerequisite:

The routine inspection for a remote server is only supported on ThinkServer servers/WenTian servers. For details of supported operating systems, see Supported operating systems.

To perform routine inspection, do the following:

  1. Launch the UpdateXpress application. See Launching the UpdateXpress application.
  2. In the Welcome window, click Next.
  3. In the Target Server window, select Manage the remote server, input the following information, and click Next.
    • IP address or Host name: BMC IP address or host name of the target system.

    • User Name: BMC user name of the target system.

    • Password: BMC password of the target system.

    • Port: BMC CIM or RSET port number. If users do not input, the default port is used.

    Note
    If users are not intended to check the BMC server certificate and SFTP/HTTPS server key fingerprint, select Accept BMC server's certificate and SFTP/HTTPS server's key fingerprint by default, and click Next.
  4. In the Task window, select Routine Inspection, and click Next.
  5. In the Routine Inspection Setting window, select Health Check or Asset Information Collect, and click Next.
  6. In the Routine Inspection Execute window, select Execute, and click Next after the process is completed.
  7. In Routine Inspection Report window, click Select to modify the path, click Save to save the report to the target path, and click Next.
  8. In the Finish window, check the updates, and click Close to exit.