Verifying a successful switchback
After performing the switchback, you want to confirm that all aggregates and storage virtual machines (SVMs) are switched back and online.
- Verify that the switched-over data aggregates are switched back: aggr show
Example
In the following example, aggr_b2 on node B2 has switched back:
node_B_1::> aggr show
Aggregate Size Available Used% State #Vols Nodes RAID Status
--------- -------- --------- ----- ------- ------ ---------------- ------------
...
aggr_b2 227.1GB 227.1GB 0% online 0 node_B_2 raid_dp,
mirrored,
normal
node_A_1::> aggr show
Aggregate Size Available Used% State #Vols Nodes RAID Status
--------- -------- --------- ----- ------- ------ ---------------- ------------
...
aggr_b2 - - - unknown - node_A_1 - Verify that all sync-destination SVMs on the surviving cluster are dormant (showing an Admin State of stopped) and the sync-source SVMs on the disaster cluster are up and running: vserver show -subtype sync-source
Example
node_B_1::> vserver show -subtype sync-source
Admin Root Name Name
Vserver Type Subtype State Volume Aggregate Service Mapping
----------- ------- ---------- ---------- ---------- ---------- ------- -------
...
vs1a data sync-source
running vs1a_vol node_B_2 file file
aggr_b2
node_A_1::> vserver show -subtype sync-destination
Admin Root Name Name
Vserver Type Subtype State Volume Aggregate Service Mapping
----------- ------- ---------- ---------- ---------- ---------- ------- -------
...
cluster_A-vs1a-mc data sync-destination
stopped vs1a_vol sosb_ file file
aggr_b2Sync-destination aggregates in the MetroCluster configuration have the suffix "-mc" automatically appended to their name to help identify them.
- Confirm that the switchback operations succeeded by using the metrocluster operation show command.
If the command output shows... Then... That the switchback operation state is successful. The switchback process is complete and you can proceed with operation of the system. That the switchback operation or switchback-continuation-agent operation is partially successful. Perform the suggested fix provided in the output of the metrocluster operation show command.
After you finish
You must repeat the previous sections to perform the switchback in the opposite direction. If site_A did a switchover of site_B, have site_B do a switchover of site_A.
Give documentation feedback