在 MetroCluster IP 配置中的替换控制器模块上引导至 ONTAP
必须将灾难站点的替换节点引导至 ONTAP 操作系统。
关于本任务
此任务在处于维护模式下从灾难站点的节点开始。
- 在其中一个替换节点上,退出到装入程序提示符处:halt
- 显示引导菜单:boot_ontap menu
- 从引导菜单中,选择选项 6:Update flash from backup config(从备份配置中更新闪存)。
系统将引导两次。在提示继续时应回答 yes。第二次引导后,在提示系统标识不匹配时应回答
y。注如果未清除使用过的替换控制器模块的 NVRAM 内容,则可能会显示混乱消息:PANIC: NVRAM contents are invalid...。如果发生这种情况,请再次将系统引导至 ONTAP 提示符位置(boot_ontap menu)。然后,您需要执行根恢复。请联系技术支持以获取帮助。
示例
确认是否继续提示:
Selection (1-9)? 6
This will replace all flash-based configuration with the last backup to
disks. Are you sure you want to continue?: yes系统标识不匹配提示:
WARNING: System ID mismatch. This usually occurs when replacing a boot device or NVRAM cards!
Override system ID? {y|n} y - 从幸存站点上验证是否已将正确的伙伴系统标识应用于节点:metrocluster node show -fields node-systemid,ha-partner-systemid,dr-partner-systemid,dr-auxiliary-systemid
示例
在此示例中,以下新系统标识应出现在输出中:
Node_A_1:1574774970
Node_A_2:1574774991
metrocluster node show -fields node-systemid,ha-partner-systemid,dr-partner-systemid,dr-auxiliary-systemid
dr-group-id cluster node node-systemid ha-partner-systemid dr-partner-systemid dr-auxiliary-systemid
----------- ---------- -------- ------------- ------ ------------ ------ ------------ ------ --------------
1 Cluster_A Node_A_1 1574774970 1574774991 4068741254 4068741256
1 Cluster_A Node_A_2 1574774991 1574774970 4068741256 4068741254
1 Cluster_B Node_B_1 - - - -
1 Cluster_B Node_B_2 - - - -
4 entries were displayed. - 如果未正确设置伙伴系统标识,必须手动设置正确的值:
- 在节点上停止并显示装入程序提示符。
- 验证 partner-sysID bootarg 的当前值:printenv
- 将值设置为正确的伙伴系统标识:setenv partner-sysid partner-sysID
- 引导节点:boot_ontap
- 如有必要,对另一个节点重复执行上述子步骤。
- 确认灾难站点的替换节点已准备好进行切回:metrocluster node show
替换节点应处于 waiting for switchback recovery 模式。如果它们处于 normal 模式,可以重新启动替换节点。进行该引导后,节点应该会处于 waiting for switchback recovery 模式。
示例
以下示例显示替换节点已准备好进行切回:
cluster_B::> metrocluster node show
DR Configuration DR
Group Cluster Node State Mirroring Mode
----- ------- ------------------ -------------- --------- --------------------
1 cluster_B
node_B_1 configured enabled switchover completed
node_B_2 configured enabled switchover completed
cluster_A
node_A_1 configured enabled waiting for switchback recovery
node_A_2 configured enabled waiting for switchback recovery
4 entries were displayed.
cluster_B::> - 验证 MetroCluster 连接配置设置:metrocluster configuration-settings connection show
示例
配置状态应显示 completed。
cluster_B::*> metrocluster configuration-settings connection show
DR Source Destination
Group Cluster Node Network Address Network Address Partner Type Config State
----- ------- ------- --------------- --------------- ------------ ------------
1 cluster_B
node_B_2
Home Port: e5a
172.17.26.13 172.17.26.12 HA Partner completed
Home Port: e5a
172.17.26.13 172.17.26.10 DR Partner completed
Home Port: e5a
172.17.26.13 172.17.26.11 DR Auxiliary completed
Home Port: e5b
172.17.27.13 172.17.27.12 HA Partner completed
Home Port: e5b
172.17.27.13 172.17.27.10 DR Partner completed
Home Port: e5b
172.17.27.13 172.17.27.11 DR Auxiliary completed
node_B_1
Home Port: e5a
172.17.26.12 172.17.26.13 HA Partner completed
Home Port: e5a
172.17.26.12 172.17.26.11 DR Partner completed
Home Port: e5a
172.17.26.12 172.17.26.10 DR Auxiliary completed
Home Port: e5b
172.17.27.12 172.17.27.13 HA Partner completed
Home Port: e5b
172.17.27.12 172.17.27.11 DR Partner completed
Home Port: e5b
172.17.27.12 172.17.27.10 DR Auxiliary completed
cluster_A
node_A_2
Home Port: e5a
172.17.26.11 172.17.26.10 HA Partner completed
Home Port: e5a
172.17.26.11 172.17.26.12 DR Partner completed
Home Port: e5a
172.17.26.11 172.17.26.13 DR Auxiliary completed
Home Port: e5b
172.17.27.11 172.17.27.10 HA Partner completed
Home Port: e5b
172.17.27.11 172.17.27.12 DR Partner completed
Home Port: e5b
172.17.27.11 172.17.27.13 DR Auxiliary completed
node_A_1
Home Port: e5a
172.17.26.10 172.17.26.11 HA Partner completed
Home Port: e5a
172.17.26.10 172.17.26.13 DR Partner completed
Home Port: e5a
172.17.26.10 172.17.26.12 DR Auxiliary completed
Home Port: e5b
172.17.27.10 172.17.27.11 HA Partner completed
Home Port: e5b
172.17.27.10 172.17.27.13 DR Partner completed
Home Port: e5b
172.17.27.10 172.17.27.12 DR Auxiliary completed
24 entries were displayed.
cluster_B::*> - 对灾难站点的另一个节点重复上述步骤。
提供反馈