重命名 Brocade FC 交换机
可能需要重命名 Brocade FC 交换机以确保整个配置中的命名一致。
- 永久禁用一个光纤网中的一台或多台交换机:switchcfgpersistentdisable以下示例显示了 switchcfgpersistentdisable 命令的输出:
示例
7840_FCIP_2:admin> switchcfgpersistentdisable
Switch's persistent state set to 'disabled'
2018/03/09-07:41:06, [ESM-2105], 146080, FID 128, INFO, 7840_FCIP_2, VE Tunnel 24 is DEGRADED.
2018/03/09-07:41:06, [ESM-2104], 146081, FID 128, INFO, 7840_FCIP_2, VE Tunnel 24 is OFFLINE.
7840_FCIP_2:admin> - 重命名一台或多台交换机:switchname new-switch-name 如果要重命名光纤网中的两台交换机,请对每台交换机使用相同的命令。以下示例显示了 switchname new-switch-name 命令的输出:
示例
7840_FCIP_2:admin> switchname FC_switch_1_B
Committing configuration...
Done.
Switch name has been changed.Please re-login into the switch for the change to be applied.
2018/03/09-07:41:20, [IPAD-1002], 146082, FID 128, INFO, FC_switch_1_B, Switch name has been successfully changed
to FC_switch_1_B.
7840_FCIP_2:admin> - 重新启动一台或多台交换机:reboot如果要重命名光纤网中的两台交换机,请重新启动这两台交换机。重新启动完成后,交换机在所有位置都会重命名。以下示例显示了 reboot 命令的输出:
示例
7840_FCIP_2:admin> reboot
Warning: This command would cause the switch to reboot
and result in traffic disruption.
Are you sure you want to reboot the switch [y/n]?y
2018/03/09-07:42:08, [RAS-1007], 146083, CHASSIS, INFO, Brocade7840, System is about to reload.
Rebooting! Fri Mar 9 07:42:11 CET 2018
Broadcast message from root (ttyS0) Fri Mar 9 07:42:11 2018...
The system is going down for reboot NOW !!
INIT: Switching to runlevel: 6
INIT:
2018/03/09-07:50:48, [ESM-1013], 146104, FID 128, INFO, FC_switch_1_B, DP0 Configuration replay has completed.
2018/03/09-07:50:48, [ESM-1011], 146105, FID 128, INFO, FC_switch_1_B, DP0 is ONLINE.
*** CORE FILES WARNING (03/09/18 - 08:00:00 ) ***
10248 KBytes in 1 file(s)
use "supportsave" command to upload
*** FFDC FILES WARNING (03/09/18 - 08:00:00 ) ***
520 KBytes in 1 file(s) - 永久启用交换机:switchcfgpersistentenable以下示例显示了 switchcfgpersistentenable 命令的输出:
示例
FC_switch_1_B:admin> switchcfgpersistentenable
Switch's persistent state set to 'enabled'
FC_switch_1_B:admin>
FC_switch_1_B:admin>
FC_switch_1_B:admin> 2018/03/09-08:07:07, [ESM-2105], 146106, FID 128, INFO, FC_switch_1_B, VE Tunnel 24 is DEGRADED.
2018/03/09-08:07:10, [ESM-2106], 146107, FID 128, INFO, FC_switch_1_B, VE Tunnel 24 is ONLINE.
FC_switch_1_B:admin>
FC_switch_1_B:admin> switchshow
switchName: FC_switch_1_B
switchType: 148.0
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 6
switchId: fffc06
switchWwn: 10:00:50:eb:1a:9a:a5:79
zoning: ON (CFG_FAB_2_RCF_9_3)
switchBeacon: OFF
FC Router: OFF
FC Router BB Fabric ID: 128
Address Mode: 0
HIF Mode: OFF
Index Port Address Media Speed State Proto
==================================================
0 0 060000 id 16G Online FC F-Port 50:0a:09:81:06:a5:5a:08
1 1 060100 id 16G Online FC F-Port 50:0a:09:83:06:a5:5a:08 - 验证是否可从 ONTAP 集群提示符处看到交换机名称变化:storage switch show以下示例显示了 storage switch show 命令的输出:
示例
cluster_A::*> storage switch show
(storage switch show)
Symbolic Is Monitor
Switch Name Vendor Model Switch WWN Monitored Status
--------------------- -------- ------- ----- ---------------- --------- -------
Brocade_172.20.7.90
RTP-FC01-510Q40
Brocade Brocade7840
1000c4f57c904bc8 true ok
Brocade_172.20.7.91
RTP-FC02-510Q40
Brocade Brocade7840
100050eb1a9aa579 true ok
Brocade_172.20.7.92
提供反馈