Skip to main content

Renaming a Brocade FC switch

You might need to rename a Brocade FC switch to ensure consistent naming throughout your configuration.

  1. Persistently disable the switch or switches in one fabric: switchcfgpersistentdisable

    The following example shows the output for the switchcfgpersistentdisable command:

    Example

    7840_FCIP_2:admin> switchcfgpersistentdisable
    Switch's persistent state set to 'disabled'
    2018/03/09-07:41:06, [ESM-2105], 146080, FID 128, INFO, 7840_FCIP_2, VE Tunnel 24 is DEGRADED.
    2018/03/09-07:41:06, [ESM-2104], 146081, FID 128, INFO, 7840_FCIP_2, VE Tunnel 24 is OFFLINE.

    7840_FCIP_2:admin>
  2. Rename the switch or switches: switchname new-switch-name

    If you are renaming both switches in the fabric, use the same command on each switch.

    The following example shows the output for the switchname new-switch-name command:

    Example

    7840_FCIP_2:admin> switchname FC_switch_1_B
    Committing configuration...
    Done.
    Switch name has been changed.Please re-login into the switch for the change to be applied.
    2018/03/09-07:41:20, [IPAD-1002], 146082, FID 128, INFO, FC_switch_1_B, Switch name has been successfully changed
    to FC_switch_1_B.
    7840_FCIP_2:admin>
  3. Reboot the switch or switches: reboot

    If you are renaming both switches in the fabric, reboot both switches. Once the reboot is complete, the switch is renamed in all places.

    The following example shows the output for the reboot command:

    Example

    7840_FCIP_2:admin> reboot
    Warning: This command would cause the switch to reboot
    and result in traffic disruption.
    Are you sure you want to reboot the switch [y/n]?y
    2018/03/09-07:42:08, [RAS-1007], 146083, CHASSIS, INFO, Brocade7840, System is about to reload.
    Rebooting! Fri Mar 9 07:42:11 CET 2018

    Broadcast message from root (ttyS0) Fri Mar 9 07:42:11 2018...

    The system is going down for reboot NOW !!
    INIT: Switching to runlevel: 6
    INIT:
    2018/03/09-07:50:48, [ESM-1013], 146104, FID 128, INFO, FC_switch_1_B, DP0 Configuration replay has completed.
    2018/03/09-07:50:48, [ESM-1011], 146105, FID 128, INFO, FC_switch_1_B, DP0 is ONLINE.

    *** CORE FILES WARNING (03/09/18 - 08:00:00 ) ***
    10248 KBytes in 1 file(s)
    use "supportsave" command to upload


    *** FFDC FILES WARNING (03/09/18 - 08:00:00 ) ***
    520 KBytes in 1 file(s)
  4. Persistently enable the switches: switchcfgpersistentenable

    The following example shows the output for the switchcfgpersistentenable command:

    Example

    FC_switch_1_B:admin> switchcfgpersistentenable
    Switch's persistent state set to 'enabled'
    FC_switch_1_B:admin>
    FC_switch_1_B:admin>
    FC_switch_1_B:admin> 2018/03/09-08:07:07, [ESM-2105], 146106, FID 128, INFO, FC_switch_1_B, VE Tunnel 24 is DEGRADED.
    2018/03/09-08:07:10, [ESM-2106], 146107, FID 128, INFO, FC_switch_1_B, VE Tunnel 24 is ONLINE.

    FC_switch_1_B:admin>


    FC_switch_1_B:admin> switchshow
    switchName: FC_switch_1_B
    switchType: 148.0
    switchState: Online
    switchMode: Native
    switchRole: Subordinate
    switchDomain: 6
    switchId: fffc06
    switchWwn: 10:00:50:eb:1a:9a:a5:79
    zoning: ON (CFG_FAB_2_RCF_9_3)
    switchBeacon: OFF
    FC Router: OFF
    FC Router BB Fabric ID: 128
    Address Mode: 0
    HIF Mode: OFF

    Index Port Address Media Speed State Proto
    ==================================================
    0 0 060000 id 16G Online FC F-Port 50:0a:09:81:06:a5:5a:08
    1 1 060100 id 16G Online FC F-Port 50:0a:09:83:06:a5:5a:08
  5. Verify that the switch name change is visible from the ONTAP cluster prompt: storage switch show

    The following example shows the output for the storage switch show command:

    Example

    cluster_A::*> storage switch show
    (storage switch show)
    Symbolic Is Monitor
    Switch Name Vendor Model Switch WWN Monitored Status
    --------------------- -------- ------- ----- ---------------- --------- -------
    Brocade_172.20.7.90
    RTP-FC01-510Q40
    Brocade Brocade7840
    1000c4f57c904bc8 true ok
    Brocade_172.20.7.91
    RTP-FC02-510Q40
    Brocade Brocade7840
    100050eb1a9aa579 true ok
    Brocade_172.20.7.92