Configuring in-order delivery or out-of-order delivery of frames on ONTAP software
You must configure either in-order delivery (IOD) or out-of-order delivery (OOD) of frames according to the fibre channel (FC) switch configuration. If the FC switch is configured for IOD, then the ONTAP software must be configured for IOD. Similarly, if the FC switch is configured for OOD, then ONTAP must be configured for OOD.
Configure ONTAP to operate either IOD or OOD of frames.
- By default, IOD of frames is enabled in ONTAP. To check the configuration details:
Enter advanced mode:
set advancedVerify the settings:
metrocluster interconnect adapter showmcc4-b12_siteB::*> metrocluster interconnect adapter show
Adapter Link Is OOD
Node Adapter Name Type Status Enabled? IP Address Port Number
------------ --------------- ------- ------ -------- ----------- -----------
mcc4-b1 fcvi_device_0 FC-VI Up false 17.0.1.2 6a
mcc4-b1 fcvi_device_1 FC-VI Up false 18.0.0.2 6b
mcc4-b1 mlx4_0 IB Down false 192.0.5.193 ib2a
mcc4-b1 mlx4_0 IB Up false 192.0.5.194 ib2b
mcc4-b2 fcvi_device_0 FC-VI Up false 17.0.2.2 6a
mcc4-b2 fcvi_device_1 FC-VI Up false 18.0.1.2 6b
mcc4-b2 mlx4_0 IB Down false 192.0.2.9 ib2a
mcc4-b2 mlx4_0 IB Up false 192.0.2.10 ib2b
8 entries were displayed.
- The following steps must be performed on each node to configure OOD of frames:
Enter advanced mode:
set advancedVerify the MetroCluster configuration settings:
metrocluster interconnect adapter showmcc4-b12_siteB::*> metrocluster interconnect adapter show
Adapter Link Is OOD
Node Adapter Name Type Status Enabled? IP Address Port Number
------------ --------------- ------- ------ -------- ----------- -----------
mcc4-b1 fcvi_device_0 FC-VI Up false 17.0.1.2 6a
mcc4-b1 fcvi_device_1 FC-VI Up false 18.0.0.2 6b
mcc4-b1 mlx4_0 IB Down false 192.0.5.193 ib2a
mcc4-b1 mlx4_0 IB Up false 192.0.5.194 ib2b
mcc4-b2 fcvi_device_0 FC-VI Up false 17.0.2.2 6a
mcc4-b2 fcvi_device_1 FC-VI Up false 18.0.1.2 6b
mcc4-b2 mlx4_0 IB Down false 192.0.2.9 ib2a
mcc4-b2 mlx4_0 IB Up false 192.0.2.10 ib2b
8 entries were displayed.Enable OOD on node
mcc4-b1
and nodemcc4-b2
: metrocluster interconnect adapter modify -node node name -is-ood-enabled truemcc4-b12_siteB::*> metrocluster interconnect adapter modify -node mcc4-b1 -is-ood-enabled true
mcc4-b12_siteB::*> metrocluster interconnect adapter modify -node mcc4-b2 -is-ood-enabled trueVerify the settings:
metrocluster interconnect adapter showmcc4-b12_siteB::*> metrocluster interconnect adapter show
Adapter Link Is OOD
Node Adapter Name Type Status Enabled? IP Address Port Number
------------ --------------- ------- ------ -------- ----------- -----------
mcc4-b1 fcvi_device_0 FC-VI Up true 17.0.1.2 6a
mcc4-b1 fcvi_device_1 FC-VI Up true 18.0.0.2 6b
mcc4-b1 mlx4_0 IB Down false 192.0.5.193 ib2a
mcc4-b1 mlx4_0 IB Up false 192.0.5.194 ib2b
mcc4-b2 fcvi_device_0 FC-VI Up true 17.0.2.2 6a
mcc4-b2 fcvi_device_1 FC-VI Up true 18.0.1.2 6b
mcc4-b2 mlx4_0 IB Down false 192.0.2.9 ib2a
mcc4-b2 mlx4_0 IB Up false 192.0.2.10 ib2b
8 entries were displayed.