Skip to main content

Loss of a single FC-to-SAS bridge

You can test the failure of a single FC-to-SAS bridge to make sure there is no single point of failure.

This test should take about 15 minutes.

This procedure has the following expected results:

  • Errors should be generated as the bridge is switched off.

  • No failover or loss of service should occur.

  • Only one path from the controller module to the drives behind the bridge is available.

  1. Turn off the power supplies of the bridge.
  2. Confirm that the bridge monitoring indicates an error: storage bridge show

    cluster_A::> storage bridge show

    Is Monitor
    Bridge Symbolic Name Vendor Model Bridge WWN Monitored Status
    ---------- ------------- ------- --------- ---------------- --------- -------
    ATTO_10.65.57.145
    bridge_A_1 Atto FibreBridge 6500N
    200000108662d46c true error
  3. Confirm that drives behind the bridge are available with a single path: storage disk error show

    cluster_A::> storage disk error show
    Disk Error Type Error Text
    ---------------- ----------------- --------------------------------------------
    1.0.0 onedomain 1.0.0 (5000cca057729118): All paths to this array LUN are connected to the same fault domain. This is a single point of failure.
    1.0.1 onedomain 1.0.1 (5000cca057727364): All paths to this array LUN are connected to the same fault domain. This is a single point of failure.
    1.0.2 onedomain 1.0.2 (5000cca05772e9d4): All paths to this array LUN are connected to the same fault domain. This is a single point of failure.
    ...
    1.0.23 onedomain 1.0.23 (5000cca05772e9d4): All paths to this array LUN are connected to the same fault domain. This is a single point of failure.