You can test the failure of a single FC-to-SAS bridge to make sure there is no single point of failure.
This test should take about 15 minutes.
This procedure has the following expected results:
Errors should be generated as the bridge is switched off.
No failover or loss of service should occur.
Only one path from the controller module to the drives behind the bridge is available.
- Turn off the power supplies of the bridge.
- Confirm that the bridge monitoring indicates an error: storage bridge show
cluster_A::> storage bridge show
Is Monitor
Bridge Symbolic Name Vendor Model Bridge WWN Monitored Status
---------- ------------- ------- --------- ---------------- --------- -------
ATTO_10.65.57.145
bridge_A_1 Atto FibreBridge 6500N
200000108662d46c true error
- Confirm that drives behind the bridge are available with a single path: storage disk error show
cluster_A::> storage disk error show
Disk Error Type Error Text
---------------- ----------------- --------------------------------------------
1.0.0 onedomain 1.0.0 (5000cca057729118): All paths to this array LUN are connected to the same fault domain. This is a single point of failure.
1.0.1 onedomain 1.0.1 (5000cca057727364): All paths to this array LUN are connected to the same fault domain. This is a single point of failure.
1.0.2 onedomain 1.0.2 (5000cca05772e9d4): All paths to this array LUN are connected to the same fault domain. This is a single point of failure.
...
1.0.23 onedomain 1.0.23 (5000cca05772e9d4): All paths to this array LUN are connected to the same fault domain. This is a single point of failure.