On each controller in the clustered ONTAP MetroCluster configuration, the FC-VI adapter and HBAs must be cabled to specific ports on the existing FC switches.
- Cable the FC-VI and HBA ports according to the following table:
Site A | Site B |
---|
Connect this Site A component and port... | FC_switch_A_1 port... | Connect this Site B component and port... | FC_switch_B_1 port... |
---|
controller_A_1 FC-VI port 1 | 32 | controller_B_1 FC-VI port 1 | 32 |
controller_A_1 HBA port 1 | 33 | controller_B_1 HBA port 1 | 33 |
controller_A_1 HBA port 2 | 34 | controller_B_1 HBA port 2 | 34 |
controller_A_2 FC-VI port 1 | 35 | controller_B_2 FC-VI port 1 | 35 |
controller_A_2 HBA 1 | 36 | controller_B_2 HBA 1 | 36 |
controller_A_2 HBA 2 | 37 | controller_B_2 HBA 2 | 37 |
- Cable each FC-SAS bridge in the first switch fabric to the FC switches.
The number of bridges varies depending on the number of SAS storage stacks.
Site A | Site B |
---|
Cable this site A bridge... | FC_switch_A_1 port... | Cable this Site B bridge... | FC_switch_B_1 port... |
---|
bridge_A_1_38 | 38 | bridge_B_1_38 | 38 |
bridge_A_1_39 | 39 | bridge_B_1_39 | 39 |
- Cable each bridge in the second switch fabric to the FC switches.
The number of bridges varies depending on the number of SAS storage stacks.
Site A | Site B |
---|
Cable this site A bridge... | FC_switch_A_2 port... | Cable this Site B bridge... | FC_switch_B_2 port... |
---|
bridge_A_2_38 | 38 | bridge_B_2_38 | 38 |
bridge_A_2_39 | 39 | bridge_B_2_39 | 39 |