FQXSPPW0002L : Power supply [PowerSupplyId] has Failed.
Power supply [PowerSupplyId] has Failed.
This message is for the use case when an implementation has detected a Power Supply has failed.
Severity
Error
Alert Category
Critical - Power
Serviceable
Yes
SNMP Trap ID
4
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- For CRPS Premium:
- Check the LEDs on the PSU. If IN LED is green and OUT LED is yellow, remove and re-install power supply unit.
- If the problem persists, collect service data log manually and contact Lenovo Support.
- For CRPS:
- Check the LED on the PSU. If the LED is yellow, remove and re-install power supply unit.
- If the problem persists, collect service data log manually and contact Lenovo Support.
Give documentation feedback