FQXSPPW0104J : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for Power Resource has asserted.
Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for Power Resource has asserted.
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or Fully Redundant to Non-redundant:Sufficient.
Severity
Warning
Alert Category
Warning - Redundant Power Supply
Serviceable
Yes
SNMP Trap ID
10
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- For CRPS Premium:
- Check the PSU LEDs:
- If IN and OUT LED are not lit, check the power cord and input voltage.
- If IN LED is green and DC LED is yellow or not lit, remove and then reinstall the power supply unit.
- If the problem persists, collect service data log.
- Contact Lenovo Support.
- For CRPS:
- Check the LED on the PSU:
- If PSU LED is yellow, check power cord and input voltage.
- If PSU LED is still yellow, remove and re-install power supply unit.
- If the problem persists, collect service data log.
- Contact Lenovo Support.