FQXSPPW0061M : PSU [SensorName] failure has transitioned to critical from a less severe state.
PSU [SensorName] failure has transitioned to critical from a less severe state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.
Severity
Error
Alert Category
Critical - Power
Serviceable
Yes
SNMP Trap ID
4
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- For CRPS Premium:
- Check the LEDs on the PSU. If IN LED is green and OUT LED is yellow, remove and re-install power supply unit.
- If the problem persists, collect service data log.
- Contact Lenovo Support.
- For CRPS:
- Check the LED on the PSU. If the LED is yellow, remove and re-install power supply unit.
- If the problem persists, collect service data log.
- Contact Lenovo Support.
Envoyer des commentaires