FQXSFMA0055G : Mirror failover operation is skipped and page retire for uncorrectable error (at [arg1]) on DIMM [arg2] is reported to OS. [arg3]
Mirror failover operation is skipped and page retire for uncorrectable error (at [arg1]) on DIMM [arg2] is reported to OS. [arg3]
Parameters
[arg1] Physical address
[arg2] DIMM Silk Label, 1-based
[arg3] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
This message is reported when the persistent UE occurred in the DIMM that triggered Mirror failover.
Severity
Warning
User Action
Complete the following steps:
- Power off the system and remove A/C power.
- Reseat the failing DIMM identified by LightPath and/or event log entry.
- Restore A/C power and power on the system.
- Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this memory error.
- If the problem persists, collect service data logs and contact Lenovo Support.
提供反馈