FQXSFPU0030N : A firmware fault has been detected in the UEFI image.
A firmware fault has been detected in the UEFI image.
This message is reported when a firmware fault has been detected in the UEFI image.
Severity
Error
User Action
Complete the following steps:
- Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this error.
- Reflash UEFI image.
- Undo recent system changes (settings or devices added). Verify that the system boots. Then, re-install options one at a time to locate the problem.
- If the problem persists, save customer's UEFI configurations, then remove and re-install CMOS battery for 30 seconds to clear CMOS contents. If it boots successfully, then restore system settings.
- If the problem persists, collect service data logs and contact Lenovo Support.NoteThe solution for this error may involve a system board replacement. If TPM encryption has been enabled, back up TPM Encryption Recovery Key.