FQXSFIO0014J : A bad option ROM checksum was detected for the device found at Bus [arg1] Device [arg2] Function [arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The physical slot number is [arg6].
A bad option ROM checksum was detected for the device found at Bus [arg1] Device [arg2] Function [arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The physical slot number is [arg6].
Severity
Error
User Action
Complete the following steps:
If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded. Reseat adapter and any attached cables.
Move adapter to a different system slot, if available.
Check Lenovo Support site for any applicable service bulletin or UEFI or adapter firmware update that applies to this error.
NoteIt may be necessary to configure slot to Gen1 or to use special utility software so that adapter firmware can be upgraded. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports ->PCIe Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
If the problem persists, collect Service Data logs and contact Lenovo Support.
NoteThe solution for this error may involve a system board replacement. If TPM encryption has been enabled, back up TPM Encryption Recovery Key.