FQXSFMA0050G : DRAM PFA threshold limit exceeded on DIMM [arg1] sub-channel [arg2] Rank [arg3] DRAM [arg4], DIMM identifier is [arg5].
DRAM PFA threshold limit exceeded on DIMM [arg1] sub-channel [arg2] Rank [arg3] DRAM [arg4], DIMM identifier is [arg5].
Parameters
[arg1] DIMM Silk Label
[arg2] Sub Channel
[arg3] Rank number
[arg4] Device number (0&1&2)
[arg5] DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU 0123456"
Severity
Warning
User Action
Complete the following steps:
- Power off the system and remove the A/C power.
- Reseat the affected DIMM.
- Restore the A/C power and power on the system.
- Check Lenovo support site for an applicable service bulletin or firmware update that applies to this memory error.
- Run advance memory test using the XClarity Provisioning Manager. Click Diagnostics > Run Diagnostics > Memory Test > Advanced Memory Test to repair the DIMM.
- If the problem persists, collect Service Data logs and contact Lenovo Support.
フィードバックを送る