Parts listing

Identify each of the components that are available for your solution with the parts listing.

For more information about ordering the parts:
  1. Go to Lenovo Data Center Support and navigate to the support page for your solution.

  2. Click Service Parts.

  3. Enter the serial number to view a listing of parts for your solution.

The parts listed in the following table are identified as one of the following:
  • Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request with no service agreement, you will be charged for the installation.

  • Tier 2 customer replaceable unit (CRU): You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for your solution.

  • Field replaceable unit (FRU): FRUs must be installed only by trained service technicians.

  • Consumable parts: Purchase and replacement of consumable is your responsibility. If Lenovo acquires or installs a consumable component at your request, you will be charged for the service.

Note
Depending on the model, your solution might look slightly different from the illustration.

Enclosure components

Figure 1. Enclosure components
Enclosure components
Table 1. Parts list
IndexDescriptionTier 1 CRUTier 2 CRUFRUConsumable and Structural part

For more information about ordering the parts shown in Enclosure components:

Enclosure parts

It is highly recommended that you check the power summary data for your server using Lenovo Capacity Planner before purchasing any new parts.

16U enclosure assembly   
2Lift handle   
3Upper EMC shield   
4Lower EMC shield   
5Manifold assembly   
6Drip sensor tray   
7Drip sensor assembly   
8System Management Module 2   
9Power supply   
10Midplane   
11External LCD diagnostics handset   

SD650 V2 components

Figure 2. SD650 V2 components
SD650 V2 components
Table 2. Parts list
IndexDescriptionTier 1 CRUTier 2 CRUFRUConsumable and Structural part

For more information about ordering the parts shown in SD650 V2 components:

Compute node parts

It is highly recommended that you check the power summary data for your server using Lenovo Capacity Planner before purchasing any new parts.

1Tray cover   
2Rear cross brace   
3Power distribution board   
4Quick connects   
5Quick connect plug covers   
6Water loop   
7DIMM comb   
8DIMM tool   
9DIMM   
10DIMM VR clamp plate   
11DIMM VR cold plate   
12System board   
13Processor   
14Processor retainer   
15Trusted Cryptographic Module (TCM)   
16ConnectX-6 kit   
17ConnectX-6 adapter   
18Adapter   
19PCIe riser cage   
20Drive cage   
212.5-inch drive (15mm)   
222.5-inch drive (7mm)   
23Front cross brace   
24Blank bezel filler   
25Water loop carrier   
26SD650 V2 cam handles   
27M.2 retainer clip   
28M.2 backplane   
29M.2 drive (42 mm and 80 mm)   
30SD650 V2 tray   
31CMOS battery (CR2032)   
32DWC waterloop service kit   
33SD650-N V2/ SD650-V2 Neptune DWC gap pad and putty kit   
34Upper drive conduction plate assembly   
35Heat sink peek nut   
36Cable   

SD650-N V2 components

Figure 3. SD650-N V2 components
SD650-N V2 components
Table 3. Parts listing
IndexDescriptionTier 1 CRUTier 2 CRUFRUConsumable and Structural part

For more information about ordering the parts shown in SD650-N V2 components:

GPU node parts

It is highly recommended that you check the power summary data for your server using Lenovo Capacity Planner before purchasing any new parts.

1Tray cover   
2GPU Power distribution board   
3Power distribution board   
4Rear cross brace   
5Quick connects   
6Quick connect plug covers   
7Water loop   
8DIMM comb   
9DIMM tool   
10DIMM   
11DIMM VR clamp plate   
12DIMM VR cold plate   
13M.2 backplane   
14M.2 drive (42 mm and 80 mm)   
15M.2 retainer clip   
16System board   
17GPU board   
18Processor   
19Processor retainer   
20Trusted Cryptographic Module (TCM)   
21ConnectX-6 kit   
22ConnectX-6 adapter   
23Adapter   
24PCIe riser cage   
25Drive cage (for compute node)   
262.5-inch drive (15mm)   
272.5-inch drive (7mm)   
28Front cross brace   
29Blank bezel filler   
30SD650-N V2 tray cam handles   
31Retimer clamp plate
Note
The retimer clamp plate is available only if no drive is installed in the GPU node.
   
32Drive cage (for GPU node)
Note
The drive cage is available only if the drive is installed in the GPU node.
   
33Retimer board   
34SD650-N V2 tray   
35Compute node water loop carrier   
36GPU node water loop carrier   
37CMOS battery (CR2032)   
38Neptune DWC Waterloop service kit   
39SD650-N V2/ SD650-V2 Neptune DWC gap pad and putty kit   
40Upper drive conduction plate assembly   
41Heat sink peek nut   
42GPU   
43Cable