Component | SD650 V3 support configurations |
---|---|
ThinkSystem 2400W (230V) v2 Platinum PSU | 6 or 9 PSUs Mixing PSUs manufactured by different vendors is not supported. |
ThinkSystem 2600W (230V) v2 Titanium PSU | 6 or 9 PSUs |
7200W Titanium DWC PSU | 2 or 3 PSUs |
High Power Midplane | Supported |
Standard Midplane (Air PSU only) | Supported |
SMM2 | Supported |
Power policy
Component | SD650 V3 power policy |
---|---|
ThinkSystem 2400W (230V) v2 Platinum PSU | 6 PSU: 5+1 with OVS, or Non-redundancy 9 PSU: 8+1 without OVS |
ThinkSystem 2600W (230V) v2 Titanium PSU | 6 PSU: 5+1 with OVS, or Non-redundancy 9 PSU: 8+1 without OVS |
7200W Titanium DWC PSU | 2 PSUs configured as 5+1 redundancy with OVS, or Non-redundancy 3 PSUs configured as 8+1 redundancy without OVS |